Clinical Trials Directory

Trials / Unknown

UnknownNCT02880748

Effect of Water Exchange Method on Adenoma Miss Rates in Patients Undergoing Selective Polypectomy

Effect of Water Exchange Method on Adenoma Miss Rates in Patients Undergoing Selective Polypectomy: a Single-centered, Randomized Controlled Study

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
450 (estimated)
Sponsor
Air Force Military Medical University, China · Academic / Other
Sex
All
Age
18 Years – 80 Years
Healthy volunteers
Not accepted

Summary

Patients with colorectal adenomas are suggested to receive polypectomy. A substantial number of adenomas may be missed in patients with polyps found by previous colonoscopy. And water exchange (WE) method may increase the detection of missed adenoma compared with traditional air insufflation (AI) colonoscopy. The investigators aim to investigate whether water exchange colonoscopy method, compared with air insufflation method, can improve the detection of missed adenomas in patients undergoing selective polypectomy.

Detailed description

For WE method, the air pump was turned off for the full duration of insertion to avoid inadvertent air insufflations and colon elongation. Residual air in the lumen was suctioned to minimize angulations at flexures. Water at 37°C was infused with a pump (Olympus) through the biopsy channel to confirm correct tip orientation for scope advancement. The infused water was removed predominantly by suction when the colonoscope was smoothly advanced during the insertion phase, and turbid luminal water due to residual feces was exchanged by clean water until the lumen was clearly visualized. Occasionally, if it was difficult to determine whether the colonoscope tip was in the cecum, air was allowed to be insufflated for observation. If the position of the scope tip was confirmed to be not in the cecum, insufflated air would be removed by suction and the WE method would be continuously used until successful intubation. For the AI method, water was not used, and air was insufflated during insertion. Air was insufflated to distend the lumen for inspection and biopsy or polypectomy during withdrawal for both methods. Polyps will be removed by forceps biopsy (polyps size \<3mm), cold snare technique (3-6mm) or endoscopic mucosal resection (size≥6mm).

Conditions

Interventions

TypeNameDescription
OTHERWater exchange (WE) methodWater exchange (WE) method was used for insertion to the cecum. And air was insufflated to distend the lumen for inspection and biopsy or polypectomy during withdrawal procedure.
OTHERAir insufflation (AI) method.Air insufflation (AI) method was used for insertion to the cecum. And air was insufflated to distend the lumen for inspection and biopsy or polypectomy during withdrawal procedure.

Timeline

Start date
2016-08-01
Primary completion
2017-08-01
Completion
2017-08-01
First posted
2016-08-26
Last updated
2016-08-26

Locations

1 site across 1 country: China

Source: ClinicalTrials.gov record NCT02880748. Inclusion in this directory is not an endorsement.