Clinical Trials Directory

Trials / Completed

CompletedNCT02847780

Comparison of Two Technique for Assessment of Vocal Cord Movement by C-Mac Videolaryngoscope vs Airway Ultrasound.

Assessment of Vocal Cord Movement After Thyroid Surgery Using C-MAC Video-laryngoscope and Airway Ultrasound.

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
100 (actual)
Sponsor
Rajiv Gandhi Cancer Institute & Research Center, India · Academic / Other
Sex
All
Age
17 Years – 70 Years
Healthy volunteers
Not accepted

Summary

This study is planned to compare C-Mac video-laryngoscope and airway ultrasound as two novel techniques (causing least discomfort to the patients) for the detection of impaired vocal-cord movement after thyroid surgery.

Detailed description

In this prospective study 100 patients posted for Thyroid surgery will be included, after explaining the procedure and written informed consent, all included patients in the study will be assessed for vocal cord mobility by C-Mac video laryngoscope (manufactured by KARL STORZ Video Laryngoscopes) followed by airway ultrasonography (USG). Linear transducer (7.5 MHz) will be used for scanning the airway placed at the level of thyroid cartilage with 10-15 degree cephalad tilt so to get proper acoustic window and for optimal visualization of laryngeal structures. C-Mac video laryngoscope will be required for virtual visualization of glottis apertures and vocal cord movement. All patients will be scanned pre-operatively by indirect laryngoscopy to see vocal cord mobility as a reference value. Immediately after extubation the patient will be scanned for vocal cord mobility by videolaryngoscope by first examiner, After oxygenation and stabilization of haemodynamic, ultrasound of airway will be performed to study the vocal cord movement by the other examiner (blinded to the laryngoscopy finding).Visibility of false vocal cords, true vocal cords and arytenoids will be given one point each for one side, maximal score will be 6. According to points the acoustic window scoring for glottis aperture will be graded as fair (score1-2), good(score3-4) and very good(score5-6) Findings of both the examiners will be collected by the primary investigator for data collection and analysis.

Conditions

Interventions

TypeNameDescription
DEVICEActive Comparator :C-Mac VideolaryngoscopeReal time assessment of Glottic aperture at the time of extubation by videolaryngoscope
DEVICEExperimental: Airway ultrasound,Airway ultrasound using portable ultrasound machine to assess vocal cords movement.

Timeline

Start date
2016-07-20
Primary completion
2017-07-19
Completion
2017-08-10
First posted
2016-07-28
Last updated
2020-06-17

Locations

1 site across 1 country: India

Source: ClinicalTrials.gov record NCT02847780. Inclusion in this directory is not an endorsement.