Clinical Trials Directory

Trials / Completed

CompletedNCT02843828

Gait Pattern Analysis and Feasibility of Gait Training With a Walking Assist Robot in Stroke Patients and Elderly Adults

Gait Pattern Analysis and Feasibility of Gait Training With a Newly Developed Walking Assist Robot in Stroke Patients and Elderly Adults

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
56 (actual)
Sponsor
Samsung Medical Center · Academic / Other
Sex
All
Age
50 Years – 84 Years
Healthy volunteers
Not accepted

Summary

The purpose of this study was to investigate the effects of the new wearable hip assist robot developed by Samsung Advanced Institute of Technology (Samsung Electronics Co, Ltd., Korea) to gait rehabilitation in elderly adults and stroke patients.

Detailed description

Randomized, two treatment groups Number of Subjects : 54 subjects (n=27 per group) Group 1 : gait rehabilitation with hip assist robot / 10 sessions (5sessions - treadmill gait training / 5sessions - overground gait training), 30min per session Group 2 : gait rehabilitation without hip assist robot / 10 sessions (5sessions - treadmill gait training / 5sessions - overground gait training), 30min per session Primary objective is to demonstrate the effects of hip assist robot on spatio-temporal parameters measured by motion capture system (Motion Analysis Corporation, Santa Rosa, CA, USA), muscle activation patterns measured by surface electromyography (sEMG) (Noraxon Inc., Scottsdale, AZ, USA), metabolic energy cost parameters measured by portable cardiopulmonary metabolic system (Cosmed K4B2, Rome, Italy) and foot pressure distribution measured by F-Scan Mobile system (Tekscan Inc., South Boston, MA, USA). Secondary objective is to demonstrate the effects of hip assist robot on motor function improvement evaluated by Berg Balance Scale (BBS), Tinetti performance oriented mobility assessment (POMA), Korean version Modified Bathel index (K-MBI), Modified Rankin Scale (MRS), Functional Ambulation Classification (FAC), Fugl-Meyer assessment for lower extremity (FMA), Korean version Fall Efficacy Scale (K-FES), Manual Muscle Test (MMT) and Range of Motion (ROM).

Conditions

Interventions

TypeNameDescription
DEVICEgait rehabilitation with Samsung Hip Assist v1Participants will participate in 10 sessions of gait rehabilitation with Samsung Hip Assist v1 (5sessions-treadmill gait training / 5sessions-overground gait training), 30min per session
OTHERgait rehabilitation without Samsung Hip Assist v1Participants will participate in 10 sessions of gait rehabilitation without Samsung Hip Assist v1 (5sessions-treadmill gait training / 5sessions-overground gait training), 30min per session

Timeline

Start date
2016-01-02
Primary completion
2017-08-30
Completion
2017-09-01
First posted
2016-07-26
Last updated
2019-04-10

Locations

1 site across 1 country: South Korea

Source: ClinicalTrials.gov record NCT02843828. Inclusion in this directory is not an endorsement.

Gait Pattern Analysis and Feasibility of Gait Training With a Walking Assist Robot in Stroke Patients and Elderly Adults (NCT02843828) · Clinical Trials Directory