Trials / Completed
CompletedNCT02843828
Gait Pattern Analysis and Feasibility of Gait Training With a Walking Assist Robot in Stroke Patients and Elderly Adults
Gait Pattern Analysis and Feasibility of Gait Training With a Newly Developed Walking Assist Robot in Stroke Patients and Elderly Adults
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 56 (actual)
- Sponsor
- Samsung Medical Center · Academic / Other
- Sex
- All
- Age
- 50 Years – 84 Years
- Healthy volunteers
- Not accepted
Summary
The purpose of this study was to investigate the effects of the new wearable hip assist robot developed by Samsung Advanced Institute of Technology (Samsung Electronics Co, Ltd., Korea) to gait rehabilitation in elderly adults and stroke patients.
Detailed description
Randomized, two treatment groups Number of Subjects : 54 subjects (n=27 per group) Group 1 : gait rehabilitation with hip assist robot / 10 sessions (5sessions - treadmill gait training / 5sessions - overground gait training), 30min per session Group 2 : gait rehabilitation without hip assist robot / 10 sessions (5sessions - treadmill gait training / 5sessions - overground gait training), 30min per session Primary objective is to demonstrate the effects of hip assist robot on spatio-temporal parameters measured by motion capture system (Motion Analysis Corporation, Santa Rosa, CA, USA), muscle activation patterns measured by surface electromyography (sEMG) (Noraxon Inc., Scottsdale, AZ, USA), metabolic energy cost parameters measured by portable cardiopulmonary metabolic system (Cosmed K4B2, Rome, Italy) and foot pressure distribution measured by F-Scan Mobile system (Tekscan Inc., South Boston, MA, USA). Secondary objective is to demonstrate the effects of hip assist robot on motor function improvement evaluated by Berg Balance Scale (BBS), Tinetti performance oriented mobility assessment (POMA), Korean version Modified Bathel index (K-MBI), Modified Rankin Scale (MRS), Functional Ambulation Classification (FAC), Fugl-Meyer assessment for lower extremity (FMA), Korean version Fall Efficacy Scale (K-FES), Manual Muscle Test (MMT) and Range of Motion (ROM).
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | gait rehabilitation with Samsung Hip Assist v1 | Participants will participate in 10 sessions of gait rehabilitation with Samsung Hip Assist v1 (5sessions-treadmill gait training / 5sessions-overground gait training), 30min per session |
| OTHER | gait rehabilitation without Samsung Hip Assist v1 | Participants will participate in 10 sessions of gait rehabilitation without Samsung Hip Assist v1 (5sessions-treadmill gait training / 5sessions-overground gait training), 30min per session |
Timeline
- Start date
- 2016-01-02
- Primary completion
- 2017-08-30
- Completion
- 2017-09-01
- First posted
- 2016-07-26
- Last updated
- 2019-04-10
Locations
1 site across 1 country: South Korea
Source: ClinicalTrials.gov record NCT02843828. Inclusion in this directory is not an endorsement.