Clinical Trials Directory

Trials / Completed

CompletedNCT02836210

27-gauge Vitrectomy Wound Integrity: a Prospective, Randomized Trial Comparing Angled Versus Straight Entry

27-gauge Vitrectomy Wound Integrity: a Prospective, Randomized Trial Comparing Angled Versus Straight Entry in Fluid-filled Vitrectomized Eyes

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
30 (actual)
Sponsor
Wills Eye · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Accepted

Summary

To prospectively compare clinical outcomes using straight (perpendicular) versus angled trocar insertion during 27 gauge pars plana vitrectomy surgery for epiretinal membrane Primary Endpoints: Sclerotomy suture rates and incidence of suture blebs at the end of 27 gauge MIVS. Secondary Endpoints: Rate of postoperative wound-related complications such as hypotony, choroidal detachments, endophthalmitis, and sclerotomy-related retinal tears with a minimum follow-up of 30 days.

Detailed description

Microincision vitrectomy surgery (MIVS) has largely replaced use of conventional, 20-gauge vitrectomy, offering more rapid visual recovery, decreased postoperative pain and inflammation, and reduced surgical time with use of smaller diameter instruments1. Most recently, 27 gauge vitrectomy instrumentation has been introduced2, offering an additional small gauge option to the currently available 23, 25, or 25+ gauge systems. Initial experience with small gauge MIVS yielded mixed results, with early reports noting increased rates of wound-related postoperative complications including hypotony, choroidal detachments, endophthalmitis, and sclerotomy-related retinal tears3,4. However, with more experience and instrument modifications, outcomes with MIVS improved1,3. In a 2010 Ophthalmic Technology Assessment report by the American Academy of Ophthalmology, outcomes of MIVS were found comparable to that of 20 gauge vitrectomy benchmarks5. Prior studies have established that a two-stage, angled incision results in improved wound integrity with 23, 25, and 25+ MIVS systems6,7, helping to prevent complications such as post-operative endophthalmitis and hypotony. However, in the two clinical series describing outcomes of 27 gauge MIVS, a one-stage, perpendicular wound construction was performed without complication in a series of 31 patients2,8. Thus far, direct comparison between wound construction techniques (one-stage, perpendicular or two-stage, angled) has not been evaluated. The purpose of this study is to prospectively compare clinical outcomes using straight, one-stage (perpendicular) versus angled, two-stage trocar insertion during 27 gauge minimally invasive vitrectomy surgery (MIVS). The design of the study will be a randomized, clinical trial. Primary outcomes will be sclerotomy suture rates and incidence of suture blebs at the end of 27 gauge MIVS surgery for epiretinal membrane and macular pucker indications (no air or gas tamponade). Secondary endpoints will include rate of postoperative wound-related complications such as hypotony, choroidal detachments, endophthalmitis, and sclerotomy-related retinal tears with a minimum of 30 days follow-up.

Conditions

Interventions

TypeNameDescription
DEVICE27-gauge vitrectomy wound constructionConventional, 3-port pars plana vitrectomy with membrane peeling is performed for epiretinal membrane indication. Angled and straight trocar entry will be directly compared.

Timeline

Start date
2015-05-01
Primary completion
2016-07-01
Completion
2016-10-01
First posted
2016-07-18
Last updated
2016-12-01

Locations

1 site across 1 country: United States

Source: ClinicalTrials.gov record NCT02836210. Inclusion in this directory is not an endorsement.