Direct Left Ventricular Rapid Pacing Via the Valve Delivery Guide-wire in TAVI
Direct Left Ventricular Rapid Pacing Via the Valve Delivery Guide-wire in TAVI: a Randomized Study
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 300 (actual)
- Sponsor
- Groupe Hospitalier Mutualiste de Grenoble · Academic / Other
- Sex
- All
- Age
- 18 Years – 100 Years
- Healthy volunteers
- Not accepted
Summary
The purpose of this study is to determine whether a left ventricular rapid pacing using the valve delivery guide-wire in transcatheter aortic valve implantation (TAVI) reduces the overall procedure duration in comparison with the conventional method.
Detailed description
Use of temporary pacing via a right ventricular lead in TAVI is still mandatory to ensure transient cardiac standstill while predilatation is performed and the valve is being positioned and deployed. This requires an additional venous vascular access and a pacing catheter which are both likely to generate complications. This study compares the standard right ventricular rapid pacing to a new and simplified technique : a left ventricular rapid pacing is provided via the back-up 0.035 " guidewire. The cathode of an external pacemaker is placed on the tip of the 0.035" wire and the anode on a needle inserted into the groin. Insulation is ensured by the balloon or TAVI catheter.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | pacing catheter | Rapid pacing during TAVI is required to ensure transient cardiac standstill while predilatation is performed and the valve is being positioned and deployed. In the right ventricular pacing arm, rapid pacing is provided by a standard right ventricular pacing catheter. |
| DEVICE | valve delivery guidewire | Rapid pacing during TAVI is required to ensure transient cardiac standstill while predilatation is performed and the valve is being positioned and deployed. In the Left ventricular pacing arm, rapid pacing is provided via the valve-delivery guidewire inserted into the left ventricle. The cathode of an external pacemaker is placed on the external end of the guidewire using an alligator clamp. The TAVI catheter provides the necessary insulation. The anode is attached directly to the subcutaneous tissue at the femoral entry site (also using an alligator clamp). |