Effects of Automated Adjustment of Inspired Oxygen With Combined Adaptive Mechanical Backup Ventilation as Compared to Automated Oxygen Adjustment Alone in Preterm Infants With Intermittent Hypoxemic Events During Non-invasive Ventilatory Support

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
37 (estimated)
Sponsor
University of Ulm · Academic / Other
Sex
All
Age
96 Hours – 34 Weeks
Healthy volunteers
Accepted

Summary

In this 2-phase cross-over study the investigators test the hypothesis that automated adjustment of the inspired oxygen with the combined use of synchronized noninvasive SpO2-sensitive and apnea-sensitive backup-ventilation (S-NIPPV) increases the time within the intended oxygen saturation range as compared to automated FiO2 adjustment alone.

Detailed description

This study will be a randomized-controlled clinical study with cross-over design of two treatment phases of 24h duration each (1. Automated FiO2-adjustment (SPO2C), 2. combined use of automated FiO2-adjustment and SpO2-sensitive/apnea-sensitive S-NIPPV (SPO2C + BU), see Figures 1 and 2). The investigators will study two patient groups of premature infants depending on the type of respiratory support at study time: One group, where the infants are on CPAP at study time, and another group of preterm infants who are already supported by nasopharyngeal IPPV at study time. Both studies will be sufficiently powered to show a significant treatment effect if it is present. Study infants will be recruited in the neonatal ICU of the children's hospital, University of Ulm and the neonatal ICU, University of Munich. Both NICU team have participated previously in clinical trials investigated new modes of mechanical ventilation using automated ventilation adjustment in the target population. Randomization of the sequence of the two study phases will be carried out using sealed envelopes. Infants will be changed to a specific ventilator device approved for clinical use in neonates in Germany (Sophie®-Respirator, Stephan Medizintechnik GmbH, Gackenbach, Germany), which is capable to automatically adjust the FiO2 (called "SPO2C") and to apply noninvasive backup-ventilation (using a noninvasive trigger device (S-NIPPV) or non-synchronized nasal IPPV (NIPPV) based on readings of an incorporated SpO2 monitoring device (Masimo® Radical 7, averaging time 2 sec). Synchronization of NIPPV and detection of apnea is achieved by using the Graseby capsule (Stephan, Vio Healthcare Ltd, Ref. 103560103), which will be secured onto the anterior abdominal wall near to the right costal margin. Infants on CPAP (first group) will be exposed to the first study phase (SPO2C, or SPO2C + BU, Figure 1) for 24h and then will be switched to the alternate mode for 24h each. Infants, who are already on nasal IPPV (SIPPV or NIPPV) as chosen by the clinical team will be exposed to NIPPV with a standardized inflation rate of 40 breaths/min (nonsynchronized, because this seems to be the current standard of care according to the available literature) and SPO2C, or to SPO2C plus synchronized BU (starting with a rate of 80 inflations/min with stepwise weaning) and then will be switched to the alternate mode for 24h each.

Conditions

Interventions

TypeNameDescription
DEVICESaturation sensitive backup ventilation

Timeline

Start date
2016-06-01
Primary completion
2016-07-01
First posted
2016-05-17
Last updated
2016-05-17