Clinical Trials Directory

Trials / Unknown

UnknownNCT02767284

A Comparative Study of Six Methods to Measure Human Contrast Vision

UCST Studie 1 - Jämförande Studie Mellan några Befintliga Och Nyutvecklade Metoder för Att mäta Den Spektrala kontrastkänslighetsfunktionen Hos människa

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
40 (estimated)
Sponsor
Uppsala University · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Accepted

Summary

This study evaluates the relative performance of different methods to measure the human spectral contrast sensitivity function (CSF).

Detailed description

The human spectral contrast sensitivity function (CSF) is a better way to estimate human vision than letter charts commonly used by ophthalmologists, optometrists and opticians. The current methods used to measure the CSF are often unreliable, due to high variability between measurements. This study will compare four (4) new tests with two (2) currently used standard tests. The contrast sensitivity function will be measured using all of the six (6) methods three times (3) in each of the two (2) eyes at two (2) occasions. Each subjects CSF will be measured 6x3x2x2 = 72 times. In addition, for each of the CSF measurements, the time used to measure the CSF and number of background variables for the subjects will be recorded. After informed consent is obtained, the subjects will undergo a visual examination. If they match the inclusion criteria they will be included. At that time or at their earliest possible convenience, their CSF will be measured using the six methods and some background information will be recorded. The follow-up measurement occasion will occur between 4 to 6 weeks (28 to 42 days) after the first. To facilitate comparison with previous studies, the CSF-measurements (in rel. contrast/cycles/degree) will be converted to a log (Base 10 logarithm) scale. The unit will thus be log CSF (LCSF) \[log\[relative contrast\]/log\[cycles/per degree\]\].

Conditions

Interventions

TypeNameDescription
DEVICEUCST-V1A previously developed device, Uppsala Contrast Sensitivity Tester - UCST-V1, that quickly measures the human CSF in one stimulus.
DEVICEUCST-V2A refined version of the UCST-V1 that randomizes frequency order.
DEVICEUCST-V3A version that utilises eye-tracking technology to make the measurements more accurate.
DEVICEQuick-CSF (QCSF)A fast contrast sensitivity measurement method using a Bayesian algorithm.
DEVICEPelli-RobsonA standard method developed using a Sloan-letter chart with decreasing contrast.
DEVICEOptec 6500A standard test using sinusoidal gratings to measure the contrast sensitivity function.

Timeline

Start date
2016-06-01
Primary completion
2017-06-01
Completion
2017-10-01
First posted
2016-05-10
Last updated
2016-06-28

Locations

1 site across 1 country: Sweden

Source: ClinicalTrials.gov record NCT02767284. Inclusion in this directory is not an endorsement.