Trials / Unknown
UnknownNCT02740400
A Comparison Between EBUS-GS and CT-guided Lung Biopsy in Diagnosis of Peripheral Pulmonary Lesions.
Endobronchial Ultrasonography With a Guide Sheath Versus Computed Tomography-guided Transthoracic Needle Biopsy in the Diagnosis of Peripheral Pulmonary Lesions
- Status
- Unknown
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 120 (estimated)
- Sponsor
- Peking University People's Hospital · Academic / Other
- Sex
- All
- Age
- —
- Healthy volunteers
- Not accepted
Summary
This is a randomized controlled trail aiming at comparing the diagnostic value and safety of endobronchial ultrasonography with a guide sheath(EBUS-GS) and computed tomography-guided transthoracic needle biopsy(CT-TTNB) for peripheral pulmonary lesions (PPLs). Patients eligible for the inclusion criteria are diagnosed using either EBUS-GS or CT-TTNB randomly. The diagnostic indicators such as sensitivity, specificity, and accuracy are compared between the two groups. Post-procedure complications are recorded.
Detailed description
CT-TTNB is widely used in the diagnosis of PPLs and its sensitivity for lung cancer remains as high as 90%. However, the relatively high rate of complications such as pneumothorax, hemoptysis, pulmonary hemorrhage, severe chest pain, and bad tolerance in patients limits its application. EBUS-GS is an emerging technology, Kurimoto in 2004 performed transbronchial lung biopsy(TBLB) assisted by EBUS-GS, and the sensitivity of diagnosing lung cancer was 81%, and it was proved to be a safe procedure with very small amount of pneumothorax and hemoptysis. Till now there is only one randomized controlled study comparing the diagnostic value of CT-TTNB and EBUS-GS; however, it did not complete the enrollment of patients on schedule. In addition, all the other studies were retrospective. Hence this prospective study was performed to determine the diagnostic value and safety of EBUS-GS and CT-TTNB for PPLs.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| PROCEDURE | EBUS-GS | The equipment for EBUS-GS includes super-thin bronchoscope BF-P260F, endobronchial ultrasonic system EU-M30S, ultrasonic probe UM-S20-17S, and guided sheath kit K201. All facilities are provided by Olympus Co. The EBUS-GS procedure was performed by thoracic surgeons. The patient was in supine position, under general anesthesia, and provided ventilatation through laryngeal mask. First, the operator placed super-thin bronchoscope into the bronchus of interest, inserted the probe covered with GS through a work channel. Later, adjusted the bronchoscope and probe to obtain classical ultrasonic graphs. The assistant fixed the bronchoscope, pulled the probe out, and placed the brush and biopsy forceps, respectively, through the GS. This process was assisted using x-ray fluoroscope or not. |
| PROCEDURE | CT-TTNB | The devices for CT-TTNB includes Lightspeed VCT spiral CT(GE co.) and Quickcore(COOK Co.) biopsy kit. The kit includes a sheath(5cm in length and 16G in outer diameter) and a automatic biopsy needle(15cm in length and 18G in outer diameter). The patient stays in supine, prone or lateral position according to the lesion's location. The first chest CT scan is performed to confirm the location of the lesion and make an optimal entry point. Then, after sterilization and 2% lidocaine local anesthesia, the sheath is stabbed into chest wall through the entry point. The second CT scan is performed to make sure that the sheath stays in proper angle and depth. The operator places the needle through the sheath and enter the lesion. Then fire the biopsy needle and repeat the procedure twice or third time. The last CT scan is conducted to determine whether pneumothorax or hemorrhage occurred. |
Timeline
- Start date
- 2015-04-01
- Primary completion
- 2016-06-01
- Completion
- 2017-05-01
- First posted
- 2016-04-15
- Last updated
- 2016-04-15
Locations
1 site across 1 country: China
Source: ClinicalTrials.gov record NCT02740400. Inclusion in this directory is not an endorsement.