Clinical Trials Directory

Trials / Completed

CompletedNCT02715076

The Effects of Ambient Temperature and Forced-air Warming on Intraoperative Core Temperature

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
292 (actual)
Sponsor
Peking Union Medical College Hospital · Academic / Other
Sex
All
Age
18 Years – 80 Years
Healthy volunteers
Not accepted

Summary

The purpose of this study is to determine: 1. the effect of ambient temperature on the rate of core temperature change from 1 to 3 hours after induction of anesthesia (linear phase of the hypothermia curve) in major operations lasting at least a couple of hours and 2. whether the relationship between ambient temperature and rate of core temperature change is different for patients who are or are not warmed with forced-air.

Detailed description

Each patient will be randomly assigned to ambient temperature of 19°C, 21°C, or 23°C. Using a factorial approach, patients will also be randomly assigned to passive insulation or forced-air warming, stratified by the three types of surgery listed below. Group allocation will be based on computer generated codes (randomly permuted block sizes) prepared by Department of OUTCOMES RESEARCH statisticians using SAS statistical software. Allocation of consented patients to designated ambient temperature and forced-air vs. passive insulation will be via a web site that will be accessed by investigators in Bejing about 90 minutes before surgery. Patients assigned to passive insulation will be covered as usual with a cotton gown and single layer of cloth surgical draping. Patients assigned to forced-air warming will also be covered with a gown and surgical drapes, but a forced-air cover (Bair hugger 63500, 3M) will be inserted between the gown and the skin surface. A lower-body cover (about 91 by 221 cm) will be positioned so the lower end of the forced-air segments extend from the ankles upward for the entire length of the cover in thoracic and abdominal cases. The cover's foot drape will extend over the feet, and in turn be covered by the surgical drape. An upper-body forced-air cover will similarly be applied for patients having hip arthroplasties. The forced-air cover will be connected to a Bair Hugger blower and #635 covers set to "high" (≈43°C). Ambient temperature will be adjusted to the designated temperature about an hour before a patient enters the operating room and adjusted as necessary to maintain the designated temperature throughout surgery. General anesthesia will be induced as per usual clinical routine. Neuraxial (epidural or spinal) and other regional blocks are permitted. Any patients whose core temperature decreases to less than 34.5°C will be actively warmed with forced air and the ambient temperature increases to the extent practical.

Conditions

Interventions

TypeNameDescription
OTHERAmbient Temperature 19°CAmbient Temperature 19°C
OTHERAmbient Temperature 21°CAmbient Temperature 21°C
OTHERAmbient Temperature 23°CAmbient Temperature 23°C
DEVICEForced-air cover (Bair hugger 63500, 3M)Patients assigned to forced-air warming will also be covered with a gown and surgical drapes, but a forced-air cover (Bair hugger 63500, 3M) will be inserted between the gown and the skin surface.
OTHERPassive insulationPatients assigned to passive insulation will be covered as usual with a cotton gown and single layer of cloth surgical draping.

Timeline

Start date
2016-01-01
Primary completion
2016-12-01
Completion
2016-12-01
First posted
2016-03-22
Last updated
2021-05-11
Results posted
2021-04-06

Locations

1 site across 1 country: China

Source: ClinicalTrials.gov record NCT02715076. Inclusion in this directory is not an endorsement.