Trials / Unknown
UnknownNCT02698592
Evaluation of Thermocool SF Catheter on the Common Cavo-tricuspid Isthmus Dependent Atrial Flutter Ablation
Comparative Study to Assess Safety and Efficacy of Catheters CelsiusTMDS® 8 mm, Thermocool® 3.5 mm of Irrigated Tip and Thermocool® SF in the Treatment of Cavo-tricuspid Isthmus Dependent Atrial Flutter
- Status
- Unknown
- Phase
- Phase 4
- Study type
- Interventional
- Enrollment
- 150 (actual)
- Sponsor
- Hospital Universitario Central de Asturias · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
The purpose of this study is to determine whether the Thermocool SF ® system is at least as effective and safe as regular 8mm catheters and irrigated tip catheters in the treatment of cavo-tricuspid isthmus dependent atrial flutter.
Detailed description
The catheter of Biosense Webster Thermocool SF® is characterized by a porous, thin-walled tip allowing a uniform cooling of the catheter tip and so, achieving increased efficiency in cooling. This allows to reduce the flow of irrigation and power output while achieving similar tissue temperatures as the conventional irrigated catheters. There is evidence of greater efficiency of Thermocool SF® catheter in causing tissue damage, but there are no clinical studies on the specific treatment of common atrial flutter. Investigators hypothesize that the Thermocool SF® system is at least as effective and safe in the treatment of cavo-tricuspid isthmus dependent atrial flutter as conventional and 8 mm irrigated tip catheters. 150 patients with common atrial flutter were randomized to 3 groups of 50 patients and each group underwent ablation catheter ablation with CelsiusTMDS® 8 mm, 3.5 mm irrigated tip Thermocool® or Thermocool® SF respectively. After the procedure, patients are being followed by clinical reviews, electrocardiograms at the 3rd, 6th and 12th months, 24h ECG-Holter examination at the first and 6th month and monthly phone consultation. Rate of recurrence and presence of other supraventricular arrhythmias are being recorded during follow-up.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | CelsiusTMDS® 8 mm catheter | After demonstrating cavo-tricuspidal isthmic dependant atrial flutter with a duodecapolar catheter, ablation with continuous tissue lesion will be performed with CelsiusTMDS® 8 mm catheter, until complete isthmic block is achieved. |
| DEVICE | Thermocool® 3.5 mm catheter of irrigated tip | After demonstrating cavo-tricuspidal isthmic dependant atrial flutter with a duodecapolar catheter, ablation with continuous tissue lesion will be performed with Thermocool® 3.5 mm catheter of irrigated tip, until complete isthmic block is achieved. |
| DEVICE | Thermocool® SF catheter | After demonstrating cavo-tricuspidal isthmic dependant atrial flutter with a duodecapolar catheter, ablation with continuous tissue lesion will be performed with Thermocool® SF catheter, until complete isthmic block is achieved. |
Timeline
- Start date
- 2012-01-01
- Primary completion
- 2015-12-01
- Completion
- 2016-12-01
- First posted
- 2016-03-03
- Last updated
- 2016-03-03
Locations
1 site across 1 country: Spain
Source: ClinicalTrials.gov record NCT02698592. Inclusion in this directory is not an endorsement.