Clinical Trials Directory

Trials / Unknown

UnknownNCT02687568

Values of Enhanced Monitoring by EEG Recording (Narcotrend) for Sedation in Colonoscopy

Values of Enhanced Monitoring by EEG Recording ( Narcotrend ) as an Adjunct to Standard Monitoring for Sedation in Colonoscopy

Status
Unknown
Phase
Study type
Observational
Enrollment
200 (estimated)
Sponsor
Ruhr University of Bochum · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

Endoscopic examinations and particularly long-lasting interventions can be uncomfortable for patients. Pain and vasovagal reactions are common. Therefore, the implementation is generally recommended under sedation and also carried out in practice here. The vital signs monitoring to avoid complications is dictated by current national guidelines. Necessary measures of monitoring include pulse oximetry and blood pressure measurements. In patients with severe heart disease an ECG recording should be used additionally. Moreover, the guidelines require that the sedation is clinically monitored continuously to avoid an unwanted anesthetic stage. Such evaluation, however, is often difficult under clinical conditions and even counterproductive, since a constant response and tactile stimulation of the patient (to check clinically the depth level of sedation ), interrupts endoscopic complex intervention. However, clinical most relevant aspect is the avoidance of unrecognized transition of patients from the stage of deep sedation in an anesthetic stage. Current recommendations do not take into account new study results from a gender perspective, which showed that women and men need a different wake-up time using the EEG derivation means by using the Narcotrend after total intravenous anesthesia, which may be due to different total doses of sedatives needed. However, the research group has been demonstrated in a previous study that most likely caused by the use of EEG monitoring (Narcotrend) an effective adaptation of sedation, in particular a more rapid recovery time by a lower dose of the administered sedative for a continuous sedation stage D0-D2 endoscopic retrograde cholangiopancreatography-(ERCP). In the presented study the investigators evaluate the extent of gender differences in the wake-up time after sedation with propofol during colonoscopy when using EEG monitoring.

Detailed description

Endoscopic examinations and particularly long-lasting interventions can be uncomfortable for patients. Pain and vasovagal reactions are common. Therefore, the implementation is generally recommended under sedation and also carried out in practice here. In interventional and longer lasting interventions (for example colonoscopy, endoscopic ultrasonography, ERCP) as opposed to purely diagnostic examinations is often deep sedation.Use of propofol in terms of sedation efficacy and the wake-up time or quality is superior to the use of benzodiazepines (plus opiates) , while patient safety is the same. The vital signs monitoring to avoid complications is dictated by current national guidelines. Necessary measures of monitoring include pulse oximetry and blood pressure measurements. In patients with severe heart disease an ECG recording should be used additionally. Moreover, the guidelines require that the sedation is clinically monitored continuously to avoid an unwanted anesthetic stage. Such evaluation, however, is often difficult under clinical conditions and even counterproductive, since a constant response and tactile stimulation of the patient (to check clinically the depth level of sedation ), interrupts endoscopic complex intervention. However, clinical most relevant aspect is the avoidance of unrecognized transition of patients from the stage of deep sedation in an anesthetic stage. Current recommendations do not take into account new study results from a gender perspective, which showed that women and men need a different wake-up time using the EEG derivation means by using teh Narcotrend after total intravenous anesthesia, which may be due to different total doses of sedatives needed. However, the research group has beendemonstrated in a previous study that most likely caused by the use of EEG monitoring (Narcotrend) an effective adaptation of sedation, in particular a more rapid recovery time by a lower dose of the administered sedative for a continuous sedation stage D0-D2 endoscopic retrograde cholangiopancreatography-(ERCP). In the presented study investigators evaluate the extent of gender differences in the wake-up time after sedation with propofol during colonoscopy when using EEG monitoring. Included are patients who undergo diagnostic or therapeutic colonoscopy, which is performed under sedation with propofol.

Conditions

Interventions

TypeNameDescription
OTHEREEG monitoringValue of EEG monitoring as adjunct to standard monitoring

Timeline

Start date
2014-05-01
Primary completion
2016-04-01
Completion
2016-07-01
First posted
2016-02-22
Last updated
2016-03-08

Locations

1 site across 1 country: Germany

Source: ClinicalTrials.gov record NCT02687568. Inclusion in this directory is not an endorsement.