Clinical Trials Directory

Trials / Unknown

UnknownNCT02666300

To Compare the Incidence of POST Between a TaperGuard ETT and Cylindrical-shaped ETT Under High Cuff Pressure

To Compare the Incidence of Postoperative Sore Throat Between a TaperGuardEndotracheal Tube(ETT)and a Cylindrical-shaped ETT Under Highcuffpressure:A Randomized,Double-blindTrial.

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
40 (estimated)
Sponsor
The Second Affiliated Hospital of Dalian Medical University · Academic / Other
Sex
All
Age
18 Years – 75 Years
Healthy volunteers
Accepted

Summary

Postoperative Sore Throat (POST) is supposed to be the most frequently occurred respiratory complication related to endotracheal intubation .Whether the new type of ETT(TaperGuard ETT) to decrease or to increase the complications of general anesthesia compared with Cylindrical-shaped ETT is still unknown .In this study ,we will compare the different incidence of complications following general anesthesia between TaperGuard ETT and Cylindrical-shaped ETT under high endotracheal tube cuff pressure.

Detailed description

BACKGROUND:Postoperative Sore Throat (POST) is supposed to be the most frequently occurred respiratory complication related to endotracheal intubation .Endotracheal tube size ,airway manipulation ,patients position et al. have been recognized as the factors affecting Postoperative Sore Throat .Controversy in respect of the relationship between the cuff design and POST is still existed. Whether the new type of ETT (TaperGuard ETT) to decrease or to increase the complications of general anesthesia compared with Cylindrical-shaped ETT is still unknown .In this study ,we will compare the different incidence of complications following general anesthesia between TaperGuard ETT and Cylindrical-shaped ETT under high endotracheal tube cuff pressure. METHODS:Patients undergoing elective non-throat and non-neck surgery were randomly allocated to receive either a TaperGuard ETT(group T) or Cylindrical-shaped ETT ( Group C).Patients received general anesthesia with different endotracheal tubes .Recoil of inflation syringe plunger was used to inflate the cuff. In the study , the cuff pressures of the endotracheal tube were recorded by a calibrated cuff manometer at two time: when the intubation was complited and before endotracheal tube was removed. The incidence and severity of Postoperative Sore Throat(POST),hoarseness, cough were collected by a single investigator blinded to the experiment at 0, 1,6, 12, and 24 hours post-operation.

Conditions

Interventions

TypeNameDescription
OTHERTaperGuard ETTtracheal intubation with TaperGuard ETT

Timeline

Start date
2015-12-01
Primary completion
2016-01-01
Completion
2016-02-01
First posted
2016-01-28
Last updated
2016-01-28

Locations

1 site across 1 country: China

Source: ClinicalTrials.gov record NCT02666300. Inclusion in this directory is not an endorsement.