Trials / Completed
CompletedNCT02652481
ENABLE MRI (Magnetic Resonance Imaging)
Expanding MRI (Magnetic Resonance Imaging) Access for Patients With New and Existing ICDs (Implantable Cardioverter Defibrillator) and CRT-Ds (Cardiac Resynchronization Therapy Defibrillator)
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 500 (actual)
- Sponsor
- Boston Scientific Corporation · Industry
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
The objective of this study is to collect data to confirm the safety and effectiveness of the Image Ready™ MR (Magnetic Resonance) Conditional Defibrillation System when used in the 1.5T (Tesla) MRI environment under the labeled Conditions of Use (Phase I). Additionally, the study will assess medically necessary MR scans according to the labeled Conditions of Use to provide real-world scanning data (Phase I and Phase II).The study also aims to demonstrate the continued ability of the ImageReady MR Conditional Defibrillation System to sense and detect ventricular fibrillation (VF) post MRI scan by collecting and analyzing data from spontaneous VF episodes, "for-cause" VF inductions, and from an optional VF induction Sub-study. .
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | ImageReady MR Conditional Defibrillation System | ImageReady MR Conditional Defibrillation System Components: Device Name Device Model Number Pulse Generators Phase I and II Phase II Only \* CRT-D (IS1/DF4/IS4) VR ICD (DF4) DR ( dual chamber) ICD (IS1/DF4) ORIGEN™ MINI ICD ORIGEN EL ICD ORIGEN X4 CRT INOGEN™ MINI ICD INOGEN EL ICD INOGEN X4 CRT DYNAGEN™ MINI ICD DYNAGEN EL ICD DYNAGEN X4 CRT-D AUTOGEN ™ MINI ICD\* AUTOGEN EL ICD\* AUTOGEN X4 CRT-D\* Right Atrial Leads and Accessories FINELINE™ II Sterox FINELINE II Sterox EZ Suture Sleeves for FINELINE II Leads INGEVITY™ MRI\* Suture Sleeve for INGEVITY MRI\* IS-1 Lead Port Plug 7145 Right Ventricular Leads and Accessories RELIANCE 4-FRONT™ (DF4)\* Suture Sleeve for RELIANCE 4-FRONT leads\*; ENDOTAK RELIANCE™ (DF4) Left Ventricular Leads and Accessories ACUITY™ X4 (IS4) Suture Sleeve for ACUITY X4 leads \* May only be used internationally outside the US |
Timeline
- Start date
- 2016-01-01
- Primary completion
- 2017-04-30
- Completion
- 2018-05-04
- First posted
- 2016-01-12
- Last updated
- 2021-01-25
- Results posted
- 2019-07-16
Locations
57 sites across 9 countries: United States, Belgium, Germany, Hong Kong, Israel, Italy, Malaysia, Spain, United Kingdom
Regulatory
- FDA-regulated device study
Source: ClinicalTrials.gov record NCT02652481. Inclusion in this directory is not an endorsement.