Randomized Comparison of Sheaths for Radial Access

Randomized Comparison of Coated Slender Versus Un-coated Traditional Sheath

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
1,000 (actual)
Sponsor
Aarhus University Hospital Skejby · Academic / Other
Sex
All
Age
18 Years – 100 Years
Healthy volunteers
Accepted

Summary

Coronary angiography (CAG) and possible angioplasty (Percutaneous Coronary Intervention = PCI) can be performed by access from the groin (a. femoralis), the wrist (a. radialis) or the elbow (a. brachialis). It is well established that there is less risk of bleeding complications when using a radial access. The smaller diameters of the vessels in the forearm, however, may result in increased risk of pain during CAG/PCI via a. radialis. This is associated with vascular spasm (spasm tendency). Ultimately this means that one may have to convert to access via a. femoralis. To perform a CAG/PCI, a tube (a so-called sheath) has to be inserted in a. radialis. It is unclear whether the design of the sheaths can reduce the spasm tendency, thus reducing pain. Terumo has recently introduced a new kind of sheath, so-called Terumo Glide Slender Heath Coated (hereafter referred to as "Slender sheath"). This sheath is partly coated, partly made of a thinner material. "Slender sheath" thus has an outer diameter smaller than that of the sheath from traditional use (Terumo Radio Focus sheath, hereafter referred to as "Standard sheath"), although the inner diameter (lumen) is the same in the two sheaths. In turn, the "Slender sheath" is more fragile and far more expensive. The purpose of the present study is to evaluate whether use of slender sheath compared with standard sheath is Associated with less pain and fewer complications following CAG/PCI.

Detailed description

Study design: Randomized study Purposes: to investigate whether the use of "Slender sheath" is associated with less pain compared to use of "Standard Sheath" and less complications corresponding at the access site. Specific hypotheses: 1. Use of "Slender sheath" results in less pain related to CAG/PCI compared to use of "Standard sheath". 2. Use of "Slender sheath" is associated with fewer conversions to femoral access compared to use of "Standard sheath". 3. Use of "Slender sheath" is associated with less use of analgesic during the procedure compared to use of "Standard sheath". 4. Use of "Slender sheath" is associated with fewer cases of occlusion of a. radialis at discharge and post-examination compared to use of "Standard sheath". Time Schedule The trial will run from December 2015 until a total number of 1000 patients are included. It is expected that the data collection and publication of the results will be completed within a year. Endpoints 1. Pain related to the application of the sheath (Visual Analog Scale = VAS) 2. Maximal pain during CAG/PCI (VAS) 3. Frequency of conversions to femoral access 4. Use of analgesics (cumulative amount of mg Fentanyl given) 5. Use of sedatives (cumulative amount of mg Midazolam given) 6. Use of Verapamil (cumulative amount of mg given, used to reduce spasms) 7. Number of catheters used 8. Number of sheaths used (femoral and radial) 9. Occlusion of a. radialis at the time of discharge estimated by ultrasound of the artery 10. Occlusion of a. radialis after a month (Assumes that all patients with open vessels at discharge also have open vessels after a month. Only patients with occluded vessels at discharge will be offered a new ultrasound scan)

Conditions

Interventions

TypeNameDescription
DEVICESlender SheathComparing outcomes for two different sheaths used during radial CAG/PCI

Timeline

Start date
2015-12-01
Primary completion
2016-07-01
Completion
2016-07-01
First posted
2015-12-22
Last updated
2016-08-16

Locations

1 site across 1 country: Denmark

Source: ClinicalTrials.gov record NCT02637843. Inclusion in this directory is not an endorsement.