Trials / Completed
CompletedNCT02634047
Use of McGrath Videolaryngoscope to Assist Transesophageal Echocardiography Probe Insertion in Intubated Patients
Use of McGrath Videolaryngoscope to Assist Transesophageal Echocardiography Probe Insertion in Intubated Patients: A Prospective Randomized Controlled Trial
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 80 (actual)
- Sponsor
- Antalya Training and Research Hospital · Other Government
- Sex
- All
- Age
- 18 Years – 70 Years
- Healthy volunteers
- Not accepted
Summary
The primary aim of this study is to investigate the difference in the first attempt and overall success rate of different techniques for insertion of transesophageal echocardiography. Secondary aim is to investigate the difference of the duration of insertion using the selected technique, complications during insertion such as oropharyngeal mucosal injury and hematoma.
Detailed description
Eighty adult patients, who received general anaesthesia for elective open heart surgeries that required transesophageal echocardiography insertion, will be randomized by means of a computer-generated randomization order into two groups: Conventional group (Group C), and videolaryngoscope group (group VL). Success rate of the selected technique (first attempt and overall), duration of insertion for selected technique, complications such as oropharyngeal mucosal injury and hematoma will be noted.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | conventional technique | transesophageal echocardiography probe was inserted using a traditional blind insertion technique. |
| DEVICE | videolaryngoscope technique | transesophageal echocardiography probe was advanced into esophagus under direct vision using videolaryngoscope |
Timeline
- Start date
- 2015-09-01
- Primary completion
- 2015-11-01
- Completion
- 2015-11-01
- First posted
- 2015-12-17
- Last updated
- 2015-12-17
Locations
1 site across 1 country: Turkey (Türkiye)
Source: ClinicalTrials.gov record NCT02634047. Inclusion in this directory is not an endorsement.