Trials / Completed
CompletedNCT02617680
Factors Affecting the Effective End-tidal Concentration of Desflurane Anaesthesia
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 80 (actual)
- Sponsor
- University Hospital Hradec Kralove · Academic / Other
- Sex
- All
- Age
- 18 Years – 78 Years
- Healthy volunteers
- Not accepted
Summary
There is accumulating evidence that inappropriate depth of anaesthesia is associated with increased risk of postoperative complications including risk of death. The aim of this study was to identify factors determining the effective end-tidal concentration (EEtC) of desflurane, duration of wash in and wash out phase, and to estimate the risk of perioperative awareness in patients undergoing elective neurosurgical procedure.
Detailed description
All patients with American Society of Anesthesiologists (ASA) physical status I-III scheduled for elective neurosurgical procedure under general anaesthesia are studied. In each individual, the manufacturer recommended age-corrected end-tidal concentrations of desflurane is set and achieved initially. Individual effective end-tidal concentration (EEtC) of desflurane is then defined according to entropy parameters and maintained in the targeted range of static and response entropy 40-50. Effective analgesia is maintained according to surgical plethysmographic index (SPI) and dose of muscle relaxants according to neuromuscular transmission monitoring (TOF). Comorbidity, regular intake of alcohol and medication, smoking, sex, weight, height, and age are recorded. Postoperative questionnaire is used to reveal the intraoperative awareness.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DRUG | desflurane - oxygen in air | The manufacturer recommended age-corrected end-tidal concentrations of desflurane in air should be set and achieved initially. Individual EEtC of desflurane will be defined according to entropy parameters and maintained in the targeted range of static and response entropy 40-50 |
| DRUG | desflurane - oxygen in nitric oxide | The manufacturer recommended age-corrected end-tidal concentrations of desflurane with nitric oxide - oxygen should be set and achieved initially. Individual EEtC of desflurane will be defined according to entropy parameters and maintained in the targeted range of static and response entropy 40-50 |
Timeline
- Start date
- 2015-02-01
- Primary completion
- 2015-12-01
- Completion
- 2015-12-01
- First posted
- 2015-12-01
- Last updated
- 2016-10-18
Locations
1 site across 1 country: Czechia
Source: ClinicalTrials.gov record NCT02617680. Inclusion in this directory is not an endorsement.