TerminatedNCT02617160

Evaluation of Automated Insulin Pump Settings Using the Advisor Pro (Previously Called) MD-Logic Pump Advisor-three Segments Study

Status
Terminated
Phase
N/A
Study type
Interventional
Enrollment
50 (actual)
Sponsor
Rabin Medical Center · Academic / Other
Sex
All
Age
6 Years – 30 Years
Healthy volunteers
Not accepted

Summary

Pump therapy is gaining popularity as a treatment mode for patients with type 1 diabetes. Utilizing pump therapy requires the development and application of a new spectrum of theoretical knowledge and practical skills by the patient. Furthermore, occasionally there is a need to tailor the pump settings, i.e. the insulin correction factor, carbohydrate ratio, basal plan and insulin activity time, in order to optimize and improve glucose control. These adjustments are based on collected information including insulin delivery, blood glucose measurements, continuous glucose monitoring data, meals and so on. Analyzing this multitude of information and data is overwhelming for many of the patients, caregivers and health care providers. Unfortunately, not all physicians have the needed expertise to fully fulfill this task, and for those who do, it is time consuming. Thus, a summary of the data with insulin dose adjustment suggestions is missing. An automated tool for pump setting adjustments will improve glycemic control without escalating the burden on patients and the health care system. Such advisor can assist the professional team during routine follow-up and the patients between visits. To address this challenge, the investigators developed the MD-Logic Pump Advisor (MDPA), which automatically analyses treatment information, learns patient's needs and accordingly suggests adjustments in insulin dosing. The MDPA uses information gathered from glucose monitoring, insulin dosing and meal data during daily routine home care. Following a 5 minute data collection and analysis, the algorithm learns and suggests pump-setting changes for optimization of glucose control. This study aims to evaluate the efficacy and safety of the Advisor Pro. The study will include three segments: Segment A - a randomized controlled parallel study, Segment B- a clinic prospective study during which the Advisor Pro will be evaluated during routine clinical visits as an added tool for physicians and Segment C- a clinical prospective parallel study for patients treated with pump therapy and SMBG only.

Conditions

Interventions

TypeNameDescription
DEVICEMD-Logic Pump AdvisorInsulin pump settings (i.e, basal plan, correction factor, carbohydrate ratio and insulin activity time) will be adjusted using the MD-Logic Pump Advisor
OTHERControl GroupInsulin pump settings (i.e, basal plan, correction factor, carbohydrate ratio and insulin activity time) will be adjusted by the medical team in accordance to the regular practice

Timeline

Start date
2016-05-01
Primary completion
2018-12-01
Completion
2018-12-01
First posted
2015-11-30
Last updated
2018-12-21