Analysis of Surface EKG Signals to Identify Myocardial Dysfunction in Patients at Risk for Coronary Artery Disease

Multidimensional Wavelet Analysis of Surface Electrocardiogram for Identifying Subclinical Myocardial Dysfunction in Patients at Risk for Coronary Artery Disease

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
200 (actual)
Sponsor
Icahn School of Medicine at Mount Sinai · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

1. The MyoVista device is capable of detecting surface electrocardiogram signals and sensitive in detecting coronary artery disease compared to traditional computed tomography angiography (CTA) 2. Electrophysiological signals at the cellular level of myocardium are related to specific patterns on the MyoVista device 3. Changes in MyoVista device output and can indicative of future CAD outcomes and need for revascularization

Detailed description

Background Myocardial ischemia is caused by myocardial oxygen supply and demand mismatch. Despite that coronary artery disease (CAD) is the major cause of myocardial ischemia, the symptoms may occur even in the absence of significant CAD. One of the mechanisms suggested for myocardial ischemia in these patients is microvascular ischemia (i.e. mismatch in microscopic vessels), affecting the myocardium (i.e. heart muscle) at the cellular level. A novel electrocardiographic recording method, the iECG is capable of capturing and amplifying signals from the cellular level that are much lower biologic signals than those processed by a traditional electrocardiogram (ECG). These recordings focus on early detection of myocardial abnormalities by non-linear analysis of electrical activity and physiological phenomenon. This novel assessment might be capable of detecting subclinical myocardial dysfunction in a variety of heart diseases. Specific Aims Aim#1: Study the feasibility of detection of CAD using iECG compared to computed tomographic coronary angiography (CTA). Aim#2: Study the association between patterns of iECG and myocardial dysfunction in patients without CAD compared to echocardiography. Aim#3: Study the effect of changes in iECG output on future outcomes of CAD and need for revascularization.

Conditions

Interventions

TypeNameDescription
DEVICEMyoVista deviceMyoVista device is a standard EKG device with additional capabilities in detecting cellular level myocardial electrophysiological signals. The device involves placing leads on the chest, similar to a traditional EKG device
DEVICEComputed tomographic coronary angiographyTraditional method of detecting coronary artery disease. CTA will be performed using 64-detector row or higher scanners with electrocardiographic gating in accordance with the Society of Cardiovascular Computed Tomography (SCCT) guidelines. Approximately 80 to 100 ml of intravenous contrast, followed by 50 to 80 ml of saline, will be administered at a rate of 5 ml/s via a power injector through an antecubital vein (on forearm near the elbow).
DEVICETransthoracic Echocardiography

Timeline

Start date
2015-10-01
Primary completion
2016-06-01
Completion
2016-06-01
First posted
2015-09-25
Last updated
2017-10-23

Locations

1 site across 1 country: United States

Regulatory