Ultrasound for Double Lumen Endotracheal Tube

Comparison Between Ultrasound and Clinical Assessment of the Correct Positioning of Left Double Lumen Endotracheal Tube

Status
Terminated
Phase
N/A
Study type
Interventional
Enrollment
5 (actual)
Sponsor
424 General Military Hospital · Academic / Other
Sex
All
Age
18 Years – 80 Years
Healthy volunteers
Not accepted

Summary

The patients will be allocated to 2 groups: the ultrasound group and the clinical group. The correct position of the double lumen tube will be determined by ultrasound (Sonoscape S6®) for the patients of the one group (group U) and by clinical examination for the patients of the other group (group C). The correct placement will be verified by bronchoscopy (Pentax®). The two methods will be compared in terms of sensitivity and specificity. The main purpose of the study is to determine if the ultrasound can be used for determination of the correct placement of the left sided double lumen endotracheal tube

Conditions

Interventions

TypeNameDescription
DEVICEDetermination of tube position by ultrasound.After placement of the left sided double lumen endotracheal tube, ventilation of both lungs will be verified by ultrasound (Sonoscape S6®). The ultrasound probe will be placed between the 2nd and 3rd intercostal space at the level of the midclavicular line parallel to the line. The probe will be slightly moved or tilted until the pleural line is identified. If lung sliding is identified then the ventilation of the lung will be considered adequate. The same procedure will be repeated for each lung alone, after lung separation is applied. Verification of the ultrasound findings will be performed by bronchoscopy (Pentax®). The depth of the tube will be adjusted according to the bronchoscopy findings until correct positioning is established.
OTHERDetermination of tube position by auscultation.After placement of the left sided double lumen endotracheal tube, ventilation of both lungs will be verified by auscultation of the upper lung fields. The same procedure will be repeated for each lung alone, after lung separation is applied. Verification of the ultrasound findings will be performed by bronchoscopy (Pentax®). The depth of the tube will be adjusted according to the bronchoscopy findings until correct positioning is established.

Timeline

Start date
2015-09-01
Primary completion
2017-12-01
Completion
2017-12-01
First posted
2015-09-22
Last updated
2018-01-09