Clinical Trials Directory

Trials / Withdrawn

WithdrawnNCT02534246

Head to Head Comparison of Two Needles EUS Guided FNB

A Paired Prospective, Single Blinded Study of the Diagnostic Accuracy and Specimen Adequacy of Two Endoscopic Tissue Biopsy Needles for Diagnosis Solid Pancreatic Mass

Status
Withdrawn
Phase
N/A
Study type
Interventional
Enrollment
0 (actual)
Sponsor
Milton S. Hershey Medical Center · Academic / Other
Sex
All
Age
18 Years – 89 Years
Healthy volunteers
Not accepted

Summary

The aim of this study is to evaluate and compare the diagnostic accuracy and specimen adequacy of two ultrasound biopsy needles. These are two existing FDA approved tissue biopsy regimens, with respect to diagnosis of solid pancreatic lesions.

Detailed description

EUS guided core biopsy using various needle designs and sizes, seems to be a promising technique to procure tissue in solid pancreatic masses for making an accurate histological diagnosis. EUS-guided core biopsies of pancreas may aid in patients with non-diagnostic EUS-FNA samples and institutions where they do not have on-site cytopathology available for prompt evaluation of tissue adequacy. Making an accurate diagnosis not only assists in planning appropriate treatment but also may decrease morbidity/mortality from unnecessary surgeries. Our goal is to evaluate and compare the diagnostic accuracy and specimen adequacy of the Cook Medical 25 gauge ProCore ultrasound biopsy needle and the Medtronic (Beacon) 25 gauge SharkCore ultrasound biopsy needle. We hypothesize the endoscopic ultrasound tissue biopsy will not be different in diagnostic accuracy of solid pancreatic lesions when using a 25 gauge SharkCore ultrasound biopsy needle in comparison with the 25 gauge ProCore ultrasound biopsy needle. This is a non- inferior paired, prospective, single-blind study design in which patients undergoing EUS for a solid pancreatic mass. Two biopsies with each of the two endoscopic needles of interest in this study will be used in random order. The biopsy needle passed first will be randomized, after which the two needles will be alternated for each of the remaining biopsies. Randomization will occur in permuted blocks of 3. Physician will record the ease/ difficulty of obtaining each of the 4 biopsies on a scale of 1 to 5. Also, they record the needle visibility on ultrasound. The biopsy site will be examined for evidence of bleeding. Biopsies will be sent to the pathology laboratory in a blinded fashion in coded containers, where pathologist determine the number of adequate biopsies out of two passes of each needle.The pathologist will also provide a scale of perceived diagnostic usefulness of material in a blinded fashion. Post procedure care will including a letter to referring physician with recommendations for treatment and follow up. This study include 30 patients referred to Hershey Medical Center.

Conditions

Interventions

TypeNameDescription
DEVICEUltrasound biopsy needle Echo Tip ProCoreTwo passes preformed with Echo Tip ProCore ultrasound biopsy needle (Cook Medical 25 gauge) and two passes will be performed using SharkCore ultrasound biopsy needle (Medtronic \[Beacon\] 25 gauge) from single lesion.
DEVICEUltrasound biopsy needle SharkCore

Timeline

Start date
2016-08-01
Primary completion
2016-10-01
Completion
2017-10-01
First posted
2015-08-27
Last updated
2016-09-13

Locations

1 site across 1 country: United States

Source: ClinicalTrials.gov record NCT02534246. Inclusion in this directory is not an endorsement.

Head to Head Comparison of Two Needles EUS Guided FNB (NCT02534246) · Clinical Trials Directory