The purpose of this study is to compare three different standard of care methods of double-lumen endobronchial tube (DLT) placement in patients who are scheduled to have thoracic surgery in which lung isolation is required.
Detailed description
The purpose of this study is to compare three different standard of care methods of double-lumen endobronchial tube (DLT) placement in patients who are scheduled to have thoracic surgery in which lung isolation is required. The investigators want to evaluate the technique of placement of the double-lumen endobronchial tube (DLT) using an included stylet that has been radically bent (ZU-bend) as compared to a commercial GlideRite stylet with the GlideScope and direct laryngoscopy using the Macintosh laryngoscope. A double-lumen endobronchial tube (DLT) is a breathing tube utilized to manage the airway when lung separation is needed for a surgical procedure. The investigator wants to evaluate how long it takes for successful placement of the double-lumen endobronchial tube (DLT) and assess the difficulty of the procedure experienced by the physician performing the intubation.
Conditions
- Airway Morbidity
- Intubation Complication
- Tracheal Intubation Morbidity
- Anesthesia Intubation Complication
- Failed or Difficult Intubation, Sequela
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | ZU-bend stylet | Laryngoscopy and intubation after induction of anesthesia will be done using the GlideScope and the ZU-bend stylet. The ZU-bend is a specific shaping technique of the intubating stylet that is closely related to the GlideScope blade curvature. Zu-bend stylet is withdrawn as a part of placement procedure during the DLT advancement. Thereafter, GlideScope is removed and placement of the double-lumen endobronchial tube is verified with capnography and fiberoptic bronchoscopy in the usual manner. |
| DEVICE | GlideScope | Laryngoscopy and intubation after induction of anesthesia will be done using the the GlideScope technique. The GlideScope is a video laryngoscope that provides a real-time view of the airway and tube placement during intubation. GlideScope is removed after DLT is in the trachea, and placement of the double-lumen endobronchial tube is verified with capnography and fiberoptic bronchoscopy in the usual manner. |
| DEVICE | GlideRite stylet | Laryngoscopy and intubation after induction of anesthesia will be done with the GlideScope using the GlideRite stylet. The GlideRite stylet is specifically designed to work with the GlideScope and provides the necessary rigidity and curvature to an otherwise flexible tube. GlideRite stylet is withdrawn as a part of placement procedure during the DLT advancement. Thereafter, GlideScope is removed and placement of the double-lumen endobronchial tube is verified with capnography and fiberoptic bronchoscopy in the usual manner. |
| DEVICE | Macintosh blade | Direct laryngoscopy and intubation after induction of anesthesia will be done with the Macintosh blade and a regular double-lumen endobronchial tube (DLT) stylet. The Macintosh blade is used to facilitate visualization of the larynx during double or single lumen endobronchial tube placement. After intubation the Macintosh laryngoscope is removed and the confirmation of the successful placement of the double-lumen endobronchial tube in done in the standard fashion. |
| DEVICE | Regular Double-lumen endobronchial tube (DLT) Stylet | Direct laryngoscopy and intubation after induction of anesthesia will be done with a regular double-lumen endobronchial tube (DLT) stylet and the Macintosh blade. The DLT stylet is withdrawn as a part of placement procedure during the DLT advancement. Thereafter, Macintosh laryngoscope is removed and placement of the double-lumen endobronchial tube is verified with capnography and fiberoptic bronchoscopy in the usual manner. |
Timeline
- Start date
- 2015-07-01
- Primary completion
- 2017-07-27
- Completion
- 2017-07-27
- First posted
- 2015-07-13
- Last updated
- 2018-07-27
- Results posted
- 2018-07-27
Locations
2 sites across 1 country: United States
Source: ClinicalTrials.gov record NCT02495259. Inclusion in this directory is not an endorsement.