Trials / Completed
CompletedNCT02466256
Intra and Postoperative Outcomes With 3 Injectors
Comparison of Intraoperative Performance and Incision Morphology Using Three Injector Devices : Randomized, Clinical Trial
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 120 (actual)
- Sponsor
- Iladevi Cataract and IOL Research Center · Academic / Other
- Sex
- All
- Age
- 40 Years – 85 Years
- Healthy volunteers
- Not accepted
Summary
This randomized clinical trial compares subjective performance during Intraocular lens (IOL) implantation, as well as incision enlargement and anterior segment morphology on OCT when IOL implantation was performed during microcoaxial phacoemulsification through a 2.2mm incision using one of three injectors : Manual screw type (Monarch III), Manual plunger type (Royale) and motorised injector (Autosert). Further, the investigators also looked at incision integrity by comparing ingress of trypan blue from the ocular surface into the anterior chamber.
Detailed description
In this randomized, clinical trial, three types of injectors were compared : 1. Manual, screw type injector (Monarch III) 2. Manual, plunger type injector (Royale, ASICO) 3. Motorized injector (Autosert, Alcon) Having performed a phacoemulsification through 2.2mm incision, IOL implantation was performed using a D cartridge and one of three injectors which was decided in a randomized fashion. The investigators evaluated incision enlargement at following points : at the end of phacoemulsification, and then, at the end of IOL implantation The investigators also looked at trypan blue ingress into the anterior chamber from the ocular surface. At 1 day, 1 week, and 1 month after surgery anterior segment OCT morphology was also studied. further, the surgeon was asked to subjectively grade the ease of implantation with each injector
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| PROCEDURE | Intraocular lens implantation | Intraocular lens implantation |
| DEVICE | Autosert Injector | Motorised injection device for intraocular lens implantation |
| DEVICE | Royale Injector | Manual, plunger type injection device for intraocular lens implantation |
| DEVICE | Monarch III Injector | Manual, screw type injection device for intraocular lens implantation |
Timeline
- Start date
- 2013-12-01
- Primary completion
- 2014-06-01
- Completion
- 2014-06-01
- First posted
- 2015-06-09
- Last updated
- 2015-06-09
Source: ClinicalTrials.gov record NCT02466256. Inclusion in this directory is not an endorsement.