Clinical Trials Directory

Trials / Completed

CompletedNCT02439606

GlideRite® Rigid Stylet Versus Parker Flex-It Stylet

GlideRite® Rigid Stylet Versus Parker Flex-It Stylet for Orotracheal Intubation by GlideScope

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
60 (actual)
Sponsor
King Saud University · Academic / Other
Sex
All
Age
18 Years – 50 Years
Healthy volunteers
Accepted

Summary

This prospective randomized trial evaluated Parker Flex-It stylet as an alternative to manufacturer, s GlideRite® Rigid Stylet to aid intubation with the GlideScope in patients undergoing elective non-cardiac surgery that required general anesthesia with orotracheal intubation.

Detailed description

The GlideScope® Ranger (GVL; Verathon Medical Inc., Bothell, WA, USA) is a novel portable, reusable video laryngoscope that has provided superior laryngeal visualization to facilitate tracheal intubation especially in the management of difficult airways; it provides indirect visualization of the glottis with a pronounced angle of 60° in the blade. It has separate monitor connected to the handle via a cable. The tip of the blade is equipped with high-resolution digital video camera, an LED light and an antifogging system. Unlike the Macintosh laryngoscope, an indirect laryngoscope such as the GlideScope device provides a view of the glottis without the need to align the oral pharyngeal and laryngeal axes facilitating an excellent glottic visualization. However, insertion and advancement of the endotracheal tube (ETT) may be more difficult to pass through the vocal cords than direct laryngoscopy, and trauma is possible. The GlideScope have shown to function better when used in conjunction with use of a stylet to guide insertion of endotracheal tube. The GlideRite Rigid Stylet (GRS) is a reusable rigid steel stylet, specifically designed by the manufacturer to resemble the distal part of the GVL blade for clear view of the airway, enabling quick intubation , its curvature approaches 90° with a radius of curvature of approximately 6 cm. Various investigators have recommended different curvatures of the ETT/stylet to optimally direct it into the trachea, including matching the blade's 60° angle, configuring the ETT with a 90° bend, or using a J-shaped ETT. Other potential strategies may include the use of a flexible stylet that allows active modification of the tip of the tracheal tube during use. The Parker Flex-It Directional Stylet (FIS, Parker Medical, Highlands Ranch, CO) is a 2-piece plastic stylet, can be used for oral intubation, and allows continuous adjustment of the tube curvature during an intubation to enable the tube to follow the curvature of the airway. We hypothesized that the use of Parker Flex-It stylet to guide ETT might offer some benefit over the GRS. Therefore, the purpose of this study was to determine the optimal stylet-tracheal tube strategy for use with the GlideScope® laryngoscope. We compared efficacy of the two intubating aids including GlideRite® Rigid Stylet versus Parker Flex-It stylet for orotracheal intubation in terms of the total intubation time (primary outcome), ease of intubation, the number of intubation attempts , the number of optimization man oeuvres and possible trauma (secondary outcomes) when used by experienced GlideScope operators.

Conditions

Interventions

TypeNameDescription
DEVICEGlide Rite Rigid Stylet groupIntubation with the GlideScope® video-laryngoscope and styletted the tracheal tube using manufacturer's GlideRite Rigid Stylet (GRS) (GVL - ST1; Verathon Medical Inc., Bothell, WA, USA). Time till successful intubation of the patient is calculated.
DEVICEParker Flex-It directional stylet groupIntubated with the GlideScope® video-laryngoscope and styletted the tracheal tube using Parker-Flex-It directional Stylet (Parker Medical, Colorado, USA) (Flexi-Stylet). Time till successful intubation of the patient is calculated.

Timeline

Start date
2014-05-01
Primary completion
2014-12-01
Completion
2014-12-01
First posted
2015-05-12
Last updated
2015-05-12

Source: ClinicalTrials.gov record NCT02439606. Inclusion in this directory is not an endorsement.