Clinical Trials Directory

Trials / Withdrawn

WithdrawnNCT02384629

PCI With AXXESS Biolimus A9 Eluting Bifurcation Stent in Treating Coronary Artery Bifurcation Disease

Status
Withdrawn
Phase
Phase 4
Study type
Interventional
Enrollment
0 (actual)
Sponsor
Yonsei University · Academic / Other
Sex
All
Age
19 Years – 85 Years
Healthy volunteers
Not accepted

Summary

1. To compare the safety and efficacy of AXXESS stent with conventional DES in patients with coronary artery bifurcation disease 2. To assess the impact of optical coherence tomography (OCT) guidance on clinical outcomes following the stent type

Conditions

Interventions

TypeNameDescription
DEVICEOCT-guided PCI with AXXESS stentThe AXXESS stent (Biosensors Europe SA, Morges, Switzerland) is a dedicated self-expanding bifurcation stent eluting the sirolimus analog Biolimus A9 emulsed in a biodegradable polymer. It has the advantage to preserve the ostium of both distal branches and allows additional stent implantation in the distal branches for complete lesion coverage, while reducing large stent overlap and eliminating deformation. Optical coherence tomography (OCT), has enabled the evaluation of strut coverage and arterial healing after DES implantation with a superior resolution and delineation over other imaging modalities. With using these superiorities of OCT, there have been many studies assessing the neointimal coverage following various types of DES implantation in various periods.
DEVICEOCT-guided PCI with conventional DES (Biomatrix flex stent)BioMatrix Flex is abluminal biodegradable polymer DES. Its abluminal coating is absorbed after 6 to 9months and turns the DES into a BMS. It combines the proven safety of a DES with an abluminal biodegradable polymer, the prove efficacy of BA9 and an advanced stent design. Optical coherence tomography (OCT), has enabled the evaluation of strut coverage and arterial healing after DES implantation with a superior resolution and delineation over other imaging modalities. With using these superiorities of OCT, there have been many studies assessing the neointimal coverage following various types of DES implantation in various periods.
DEVICEAngio-guided PCI with AXXESS stentThe AXXESS stent (Biosensors Europe SA, Morges, Switzerland) is a dedicated self-expanding bifurcation stent eluting the sirolimus analog Biolimus A9 emulsed in a biodegradable polymer. It has the advantage to preserve the ostium of both distal branches and allows additional stent implantation in the distal branches for complete lesion coverage, while reducing large stent overlap and eliminating deformation. We use the conventional coronary angiography.
DEVICEAngio-guided PCI with PCI with conventional DES (Biomatrix flex stent)BioMatrix Flex is abluminal biodegradable polymer DES. Its abluminal coating is absorbed after 6 to 9months and turns the DES into a BMS. It combines the proven safety of a DES with an abluminal biodegradable polymer, the prove efficacy of BA9 and an advanced stent design. We use the conventional coronary angiography.

Timeline

Start date
2015-03-01
Primary completion
2017-03-01
Completion
2017-12-01
First posted
2015-03-10
Last updated
2016-07-27

Source: ClinicalTrials.gov record NCT02384629. Inclusion in this directory is not an endorsement.