Clinical Trials Directory

Trials / Completed

CompletedNCT02345109

Clinical Trial of Transtek Body Fat Analyzer (GBF-835-N2 & Other 7 Models)

Verify the Functions and Efficiency of Transtek (Trade Mark) Body Fat Analyzer, 8 Models

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
60 (actual)
Sponsor
Leo Wang · Academic / Other
Sex
All
Age
10 Years
Healthy volunteers
Accepted

Summary

The clinical protocol of the clinical testing of this device: 1. Objective of the test: To verify the functions and efficiency of devices. 2. Test methods and procedures: Comparison Test. 3. Device Under Test (DUT): Transtek Body Fat Analyzer, Model: GBF-835-N2, GBF-835-N2 Plus, LS202-B1, LS202-B1 Plus, LS206-E1, LS206-E1 Plus, GBF-1251-B1, and GBF-1251-B1 Plus. 4. Comparison device: TRANSTEK GBF-1251-B and Tanita BC-533. 5. Study endpoints: DUT and the comparison device are substantial equivalence. 6. Statistical methodology used: Description of statistical methods.

Detailed description

1. Test Purpose: The aim of clinical test is to collect BMI, body fat, total body water, muscle mass, bone mass, calorie, and visceral fat reading value which measured by DUT and reference device. 2. Target Subject: The subject database shall contain at least 30 male and 30 female subjects and all above 10 years old. 3. Test procedures: 1. Record the name, age, gender, and height of each subject. 2. Let subject seated calmly for two minutes before test, dry the feet. 3. Use device to measure weight, body fat, total body water, bone mass, and muscle mass; record reading value. 4. For each subject, repeat 3) to get 3 pairs measurements. 5. Repeat step 1) to 4) for every device (DUT: GBF-835-N2, GBF-835-N2 Plus, LS202-B1, LS202-B1 Plus, LS206-E1, LS206-E1 Plus, GBF-1251-B1, and GBF-1251-B1 Plus; and reference device: GBF-1251-B and BC-533). 6. Repeat step 1) to 5) for each subject. 4. Note: 1. No motion and speaking are allowed during the measurement. 2. All DUT use the same algorithms and contact the patient at the same body locations (feet), and operate on the same frequency. 3. Test environment: Temperature: 22±1℃; Relative humidity: 40\~70%.

Conditions

Interventions

TypeNameDescription
DEVICETranstek DUTMeasuring weight, total body water, body fat, muscle mass, bone mass, BMI, visceral fat, and calorie. Measure each participants by Transtek DUT.
DEVICEReferenceMeasuring weight, total body water, body fat, muscle mass, bone mass, BMI, visceral fat, and calorie. Measure each participants by Reference.

Timeline

Start date
2014-12-01
Primary completion
2014-12-01
Completion
2014-12-01
First posted
2015-01-26
Last updated
2015-01-26

Locations

1 site across 1 country: China

Source: ClinicalTrials.gov record NCT02345109. Inclusion in this directory is not an endorsement.