Clinical Trials Directory

Trials / Completed

CompletedNCT02321020

Follow up of Radiofrequency Maze in Mitral Patients

Sinus Rhythm and Atrial Contractility Recovery After Radiofrequency Maze in Mitral Patients

Status
Completed
Phase
Study type
Observational
Enrollment
168 (actual)
Sponsor
Centro Cardiologico Monzino · Academic / Other
Sex
All
Age
Healthy volunteers
Not accepted

Summary

The present study aimed at evaluating mid-term results of radiofrequency modified maze procedure in mitral patients in terms of sinus rhythm and atrial contractility restoration

Detailed description

Atrial fibrillation presents with different frequencies in patients affected by structural heart diseases requiring surgery, showing a peak incidence of up to 60-80% in mitral subjects. It causes an increased risk of systemic embolism, cardiac failure development and higher limitations due to dyspnoea and fatigue on exercise. Cox-Maze technique for surgical atrial fibrillation treatment was first used in 1987 and suffered lots of modifications since then. Nowadays, most centers have replaced the "cut and sew" technique by other methods using several power sources to achieve the same target in a much easier way. One of the alternative energy source currently used is radiofrequency ablation which has been demonstrated to be a simple, safe and reproducible procedure with an acceptable success rate in terms of sinus rhythm restoration. However, organized atrial activity (sinus rhythm on surface electrocardiogram) is not always accompanied by an effective mechanical atrial contraction, whose restoration represents one of the original Maze objective. Atrial contraction is effective when A waves are found in tricuspid and/or mitral transvalvular flow using Doppler echocardiography, allowing the patient to fully profit from hemodynamic and clinical advantages of an organized atrial contraction. Predictive factors of atrial contractility recovery and, more widely, of sinus rhythm achievement after modified Maze procedures have been investigated, but, at our knowledge, a parallel deep analysis and comparison of possible determinants of both surgical ablation goals is still lacking. In the present study, the investigators describe mid-term results of concomitant modified radiofrequency Maze in a large homogeneous population of mitral patients, focusing onto common predictors of sinus rhythm and atrial contractility restoring, their time course appearance and interrelation.

Conditions

Interventions

TypeNameDescription
PROCEDURERadiofrequency maze procedureRadiofrequency energy was used to create continous endocardial and epicardial lesions mimicking most of the left atrial incisions set as described in the Cox Maze III procedure. In the first 70 patients a monopolar technology was employed (Cardioblate Surgical Ablation Pen, Medtronic Inc, Minneapolis, MN, USA - cooled tip cardioblate pen, power ranging from 25 to 35 W), while in the subset of patients who underwent surgery after July 2005 a bipolar device was used (Cardioblate BP2 Irrigated RF Surgical Ablation System, Medtronic Inc, Minneapolis, MN, USA). The tip of both types of RF probe was irrigated with saline at room temperature at a flow rate of 4-6 ml/min.
PROCEDURETransthoracic echocardiographyContemporary to clinical follow up, all patients were evaluated with 2-dimensional transthoracic echocardiography by the same cardiologist at 3,6,12 and 24 months in order to specifically monitor left atrial contractility presence.

Timeline

Start date
2002-01-01
Primary completion
2014-12-01
First posted
2014-12-22
Last updated
2014-12-22

Source: ClinicalTrials.gov record NCT02321020. Inclusion in this directory is not an endorsement.