CompletedNCT02278640

Harmonic ACE®+7 Shears in Laparoscopic Hysterectomy

Prospective, Multicenter, Study Evaluating Vessel Sealing Utilizing the Harmonic ACE®+7 Shears During Total Laparoscopic Hysterectomy

Status
Completed
Phase
Phase 4
Study type
Interventional
Enrollment
40 (actual)
Sponsor
Ethicon Endo-Surgery · Industry
Sex
Female
Age
40 Years
Healthy volunteers
Not accepted

Summary

This is a prospective, non-randomized, single arm, multicenter, study to assess the initial clinical experience with the Harmonic ACE®+7 Shears by evaluating vessel sealing during total laparoscopic hysterectomy. The study will not modify or influence current surgeon technique. Investigators will perform each procedure using the device in compliance with their standard surgical approach and product labeling. The Harmonic ACE®+7 Shears is cleared for commercial distribution and will be used in accordance with approved product labeling. The Harmonic ACE®+7 Shears will be assembled, calibrated, and/or used in accordance with manufacturer design specifications, product instructions and guidelines

Detailed description

Study Population: Subjects enrolled into this study will undergo elective total laparoscopic hysterectomy for benign indications wherein dissection and transection of the uterine vasculature is indicated. Primary Variables: Percentage of subjects achieving hemostasis at the named vessel/pedicle (UA or UP) on the left side. Percentage of subjects achieving hemostasis at the named vessel/pedicle (UA or UP) on the right side. Definition: Hemostasis of the named vessel or pedicle is a dichotomous variable (i.e. yes or no). "Yes" is defined as the hemostatic transection of the uterine vasculature (left / right) with at least one use of the device in Advanced Hemostasis mode (a completed cycle with the second activation tone heard) without the use of additional hemostatic measures (i.e. tissue sealers, cautery devices, hemoclips, staples, sutures, fibrin sealants, etc.) other than the Harmonic ACE®+7 device. Note: Multiple applications of the Advanced Hemostasis mode and/or additional applications of the device in a maximum (MAX) or minimum (MIN) mode are allowed. Secondary Endpoints: Percentage of subjects achieving hemostasis at the OP on the left and/or right side. If the study procedure also includes the transection and sealing of one or both OPs, hemostasis of the left and/or right OP will also be recorded. Hemostasis of the OP is a dichotomous variable (i.e. yes or no). "Yes" is defined as the hemostatic transection of the ovarian vasculature (left and/or right) with at least one use of the device in Advanced Hemostasis mode (a completed cycle with the second activation tone heard) without the use of additional hemostatic measures (i.e. tissue sealers, cautery devices, hemoclips, staples, sutures, fibrin sealants, etc.). Note: Multiple applications of the Advanced Hemostasis mode or the device in a MAX or MIN mode are allowed. Exploratory endpoints include: Requirement for additional measures to obtain hemostasis on the named vessel/pedicle (UA or UP and/or OP) on the left and right side Use of other energy devices (tissue sealers, cautery devices) - Graded as yes or no; if "yes", the name and type, time of application (24 hour clock). Use of additional hemostatic products (e.g. hemoclips, staples, sutures, fibrin sealants) - Graded as yes or no; if "yes", the name and type, number/volume, and time of application (24 hour clock). Complications associated with vaginal cuff healing including dehiscence or separation, infection, cellulitis, abscess, inflammation, and granulation associated with each suture used as part of the study. Adverse events attributed to the study device or procedure will be collected from time of surgery to Visit 4 (Approximately 4 to 6 weeks after study surgery or as per standard of care (SOC)). No formal sample size determination is required for this study. Approximately 40 subjects from the United States and the European Union are planned to be enrolled into this study. Global indication for use of the The Harmonic ACE®+7, 5mm Diameter Shears with Advanced Hemostasis: Indicated for soft tissue incisions when bleeding control and minimal thermal injury are desired. The instruments can be used as an adjunct to or substitute for electrosurgery, lasers and steel scalpels in general, plastic, pediatric, gynecologic, urologic, thoracic, exposure to orthopedic structures (such as spine and joint space), sealing and transection of lymphatic vessels, and other open and endoscopic procedures. The instruments allow for the coagulation of vessels up to and including 7mm in diameter, using the Advanced Hemostasis function.

Conditions

Interventions

TypeNameDescription
DEVICEHarmonic ACE®+7 ShearsVessel/pedicle sealing performance assessed for transection and sealing of the of the uterine vasculature.

Timeline

Start date
2014-10-01
Primary completion
2015-04-01
Completion
2015-06-01
First posted
2014-10-30
Last updated
2016-08-19
Results posted
2016-08-19

Locations

4 sites across 3 countries: United States, Netherlands, United Kingdom