Clinical Trials Directory

Trials / Unknown

UnknownNCT02259335

Weaning Form Mechanical Ventilation Using Extracorporeal CO2 Removal

A Pilot Study on the Use of Extracorporeal CO2 Removal During the Weaning Process From Mechanical Ventilation

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
15 (estimated)
Sponsor
IRCCS Azienda Ospedaliero-Universitaria di Bologna · Academic / Other
Sex
All
Age
18 Years – 90 Years
Healthy volunteers
Not accepted

Summary

Weaning from invasive mechanical ventilation is one of the major clinical problem especially ion those patients with a pre-existing chronic respiratory disease and chronic hypercpania. The aim of this pilot feasibility and safety trial is to assess the possibility of shorten the duration of mechanical ventilation using a device able to remove CO2 and theoretically able to allow therefore the praecox extubation

Detailed description

Weaning from invasive mechanical ventilation is one of the major clinical problem especially ion those patients with a pre-existing chronic respiratory disease and chronic hypercpania. Up to 60% of the ventilatory time is devoted in these patients to the process of weaning. These patients very often fail several weaning attempt, when a T-piece trial method is used. In this case they are also very likely to require tracheotomy. In this study we will enroll those still hypercapnic patients fitting the criteria of readiness to be wean (i.e. clinical stability, normal sensorium and good cough reflex) and failing a T-piece trail because of a rise in PaCO2 (\>20% from baseline) and/or a rapid shallow breathing index (f/VT)\> 100. After the unsuccessful trial they will be reconnected to the ventilator and they will repeat hours later the same T-piece trial once the extracorporeal CO2 removal device (DeCap) will be connected via a double lumen catheter in the femoral vein. The investigators aim to verify whether using the DeCap) the investigators will be able to avoid at the end of the T-piece trial the criteria of failure. If so, the patient will be extubated and DeCap will be continued when all of the following were achieved for at least 12 hours: respiratory rate less than 25 breaths/min; pH greater than 7.35; Paco2 less than 20% of the baseline value; and absence of use of the accessory muscles or paradoxical abdominal movements.

Conditions

Interventions

TypeNameDescription
DEVICEExtracorporeal CO2 removal deviceA device able to remove CO2 using a dedicated device connected to the patient via a double lumen catheter inserted in the femoral vein

Timeline

Start date
2014-10-01
Primary completion
2017-04-01
Completion
2017-10-01
First posted
2014-10-08
Last updated
2016-10-11

Locations

2 sites across 1 country: Italy

Source: ClinicalTrials.gov record NCT02259335. Inclusion in this directory is not an endorsement.