Trials / Completed
CompletedNCT02237482
Investigating Proximal Migration in Trabecular Metal Cups Used In Acetabular Revision Surgery
Is the Trabecular Metal Cup Associated With Lower Risk of Aseptic Loosening in Acetabular Revision Surgery?
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 100 (actual)
- Sponsor
- Sahlgrenska University Hospital · Academic / Other
- Sex
- All
- Age
- 85 Years
- Healthy volunteers
- Not accepted
Summary
This study is intended to compare the proximal migration of the tantalum design (TM) with a cemented cup used in conjunction with bone allografting in cases with major bone loss. A group of patients with good periacetabular bone stock are included to analyse the differences between the tantalum and titanium design regarding risk of loosening and differences in clinical outcome measures. Radiostereometry (RSA) is used to accurately measure migration and rotation of the revision cups.
Detailed description
Acetabular component loosening is often associated with periacetabular bone loss. Different approaches are described to address the bone defects in acetabular revision surgery. Several authors have reported inferior results when uncemented Titanium alloys and older porous coated designs are used in acetabular revisions with significant bone loss. Cemented fixation of the revision cup with impaction bone grafting (BIG), introduced more than three decades ago has today a thorough documentation. The Tantalum designs, with inherent properties such as high volumetric porosity, low modulus of elasticity and high friction against the bone, have been suggested to improve the fixation of the acetabular component. Several authors have been reporting promising short- and medium-term results using the TM designs in acetabular revisions with large periacetabular bone defects. Proximal migration measured with radiostereometry (RSA) has been suggested to predict risk for late aseptic loosening in hip prosthesis surgery. This study was primarily to compare the proximal migration of the tantalum design with a cemented cup used in conjunction with bone allografting in cases with major bone loss. A group of patients with good periacetabular bone stock are included to analyse the differences between the tantalum and titanium design. RSA is used to accurately measure migration and rotation of the revision cups.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Trilogy cup | |
| DEVICE | Trabecular metal cup (TM) | |
| DEVICE | ZCA cup |
Timeline
- Start date
- 2006-07-01
- Primary completion
- 2011-12-01
- Completion
- 2011-12-01
- First posted
- 2014-09-11
- Last updated
- 2014-09-12
Locations
1 site across 1 country: Sweden
Source: ClinicalTrials.gov record NCT02237482. Inclusion in this directory is not an endorsement.