Clinical Trials Directory

Trials / Completed

CompletedNCT02237482

Investigating Proximal Migration in Trabecular Metal Cups Used In Acetabular Revision Surgery

Is the Trabecular Metal Cup Associated With Lower Risk of Aseptic Loosening in Acetabular Revision Surgery?

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
100 (actual)
Sponsor
Sahlgrenska University Hospital · Academic / Other
Sex
All
Age
85 Years
Healthy volunteers
Not accepted

Summary

This study is intended to compare the proximal migration of the tantalum design (TM) with a cemented cup used in conjunction with bone allografting in cases with major bone loss. A group of patients with good periacetabular bone stock are included to analyse the differences between the tantalum and titanium design regarding risk of loosening and differences in clinical outcome measures. Radiostereometry (RSA) is used to accurately measure migration and rotation of the revision cups.

Detailed description

Acetabular component loosening is often associated with periacetabular bone loss. Different approaches are described to address the bone defects in acetabular revision surgery. Several authors have reported inferior results when uncemented Titanium alloys and older porous coated designs are used in acetabular revisions with significant bone loss. Cemented fixation of the revision cup with impaction bone grafting (BIG), introduced more than three decades ago has today a thorough documentation. The Tantalum designs, with inherent properties such as high volumetric porosity, low modulus of elasticity and high friction against the bone, have been suggested to improve the fixation of the acetabular component. Several authors have been reporting promising short- and medium-term results using the TM designs in acetabular revisions with large periacetabular bone defects. Proximal migration measured with radiostereometry (RSA) has been suggested to predict risk for late aseptic loosening in hip prosthesis surgery. This study was primarily to compare the proximal migration of the tantalum design with a cemented cup used in conjunction with bone allografting in cases with major bone loss. A group of patients with good periacetabular bone stock are included to analyse the differences between the tantalum and titanium design. RSA is used to accurately measure migration and rotation of the revision cups.

Conditions

Interventions

TypeNameDescription
DEVICETrilogy cup
DEVICETrabecular metal cup (TM)
DEVICEZCA cup

Timeline

Start date
2006-07-01
Primary completion
2011-12-01
Completion
2011-12-01
First posted
2014-09-11
Last updated
2014-09-12

Locations

1 site across 1 country: Sweden

Source: ClinicalTrials.gov record NCT02237482. Inclusion in this directory is not an endorsement.