Quadripolar Leads for the Management of Heart Failure Patients in the Middle East

Status
Unknown
Phase
Phase 4
Study type
Interventional
Enrollment
389 (estimated)
Sponsor
King Abdullah International Medical Research Center · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

Heart failure is the most rapidly growing cardiovascular condition in developed countries. Despite advances in medical therapy, patients with heart failure are at high risk for death and hospitalization. Cardiac Resynchronization Therapy - defibrillators (CRT-D) are an effective treatment for heart failure. Despite the high success rate of a CRT-D implant, there is a possibility of 10% that the LV lead cannot be implanted in patients undergoing a trans-venous system implantation. In this case, the patients may undergo multiple procedures before a lead is successfully implanted. These implant failures are not due to patient selection but rather to patients heart anatomy leading to lead stability problems, phrenic nerve stimulation (also called diaphragmatic stimulation) and poor electrical measurements. The phrenic nerve is not part of the heart but runs near to this area on the way to a large muscle, called diaphragm, which separates the lung space from the space containing stomach, liver, kidneys and other internal organs in the abdomen. If the lead electrode is close to this nerve, it can cause a small part of it to contract giving you an uncomfortable hiccupping sensation. In many patients, phrenic nerve stimulation is not identified until after the implant procedure when movement and postural changes bring the LV lead into closer contact with the phrenic nerve. The investigation is performed to demonstrate the equality of performance of two different modalities of optimization of the implanted device and Quartet lead, Empirical (anatomical) optimization and Right Ventricle Left Ventricle (RVLV) conduction delay optimization.

Conditions

Interventions

TypeNameDescription
OTHERElectrical optimization by RVLV Conduction Time with VectSelectVectSelect Quartet multivector testing is a programmer-based feature that provides centralized vector testing and programming with the flexibility to select the appropriate pacing vector to meet individual patient needs. The Right ventricle - Left Ventricle (RV-LV) conduction time measurement will automatically identify the RV-LV conduction time for each LV electrode .
OTHERAnatomical optimization of device and leadsPatients will be implanted with left ventricular leads which will be positioned most basal, most apical or midway in the left ventricle. This follows the physician's routine clinical practice and judgement.
DEVICEImplanted device and lead (Cardiac Resynchronization Therapy Defibrillator (CRT-D) device and SJM Quadripolar lead system)All participants will be implanted with a St Jude Medical (SJM) Cardiac Resynchronization Therapy Defibrillator (CRT-D) device and SJM Quadripolar lead system. Patients who fulfill the criteria for CRT D implant, will be invited to participate in this clinical investigation. Patients implanted with chronic leads requiring device upgrade to CRT-D can also be enrolled in the study, provided they are receiving a CRT-D device for the first time.