Trials / Completed
CompletedNCT02181075
Targeted Chemotherapy Using Focused Ultrasound for Liver Tumours
A Proof of Concept Study to Investigate the Feasibility of Targeted Release of Doxorubicin From Lyso-thermosensitive Liposomal (LTSL) Doxorubicin (ThermoDox®) Using Focused Ultrasound in Patients With Primary or Secondary Liver Tumours
- Status
- Completed
- Phase
- Phase 1
- Study type
- Interventional
- Enrollment
- 10 (actual)
- Sponsor
- University of Oxford · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
This proof of concept study proposes targeted delivery of a broad-spectrum cytotoxic agent (doxorubicin), via a specially formulated LTSL (ThermoDox®) activated by mild hyperthermia, by using focused ultrasound (FUS), to achieve enhanced intra-tumoural doxorubicin concentrations for the same systemic dose. Adult patients with incurable confirmed hepatic primary or secondary tumours received a single cycle of LTLD, followed by ultrasound-mediated hyperthermia to a single target liver tumour. The primary endpoint relates to evidencing enhanced delivery of doxorubicin from LTLD at the target tumour site, by comparing intratumoural concentrations of the drug before and after focused ultrasound (FUS) exposure.
Detailed description
To date, purely pharmacological approaches have failed to address what is essentially a threefold challenge: (i) to deliver therapeutically significant concentrations of active agents to the tumour vasculature while minimizing off target effects; (ii) to release the therapeutic agent 'on-demand' at the target site; and, (iii) to improve the distribution and spread of the therapeutic agent against the intra-tumoural pressure gradient in order to achieve a therapeutically relevant concentration throughout the tumour. Recent pre-clinical studies performed at Oxford using ThermoDox® released using FUS has shown that increased uptake at the target site is achievable. Hence there is great promise in using this combination therapy to achieve increased tumour uptake and local dose for the equivalent dose of doxorubicin used in systemic chemotherapy for human subjects, which has a well established and safe toxicity profile. The first extracorporeal FUS device in Europe was used for a study performed at Oxford between 2002 and 2004. This single centre trial was sponsored by the University of Oxford. The recruiting study site was Oxford University Hospitals NHS Trust, where there is extensive clinical FUS experience. The study is split into two parts. Part I identified optimal FUS exposure parameters for a range of patient BMIs and tumour locations within the liver using real time thermometry data from an implanted thermistor. After at least 5 and no more than 14 participants have had the intervention using real-time thermometry, data was reviewed by the Trial Management Group (TMG) to confirm readiness to proceed without real-time thermometry. Part II, which did not require thermistor implantation, is designed to reflect how the therapy would be implemented in clinical practice. Participants received treatment for 1 day and are followed up for 30 days. All evaluable participants from both Part I and Part II were included in the endpoint analysis. Doxorubicin concentrations were directly determined from tissue biopsies of the target tumour, using a Good Laboratory Practice-validated high performance liquid chromatography (HPLC) assay, based on previously published methods. If this study demonstrates successful targeted drug delivery in human subjects using LTSLs released by mild-hyperthermia, this could potentially transform the future of chemotherapy in clinical practice; targeted therapy using LTSLs containing other chemotherapeutic agents triggered non-invasively by mild hyperthermia could be applied to any solid organ cancer.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DRUG | ThermoDox® (LTLD) | ThermoDox® (LTLD) infusion at a dose of 50mg/m2 whilst under general anaesthetic during intervention (Day 1) |
| DEVICE | Focused Ultrasound of Target Liver Tumour | Whilst the ThermoDox® was circulating in the blood stream, the JC200 Therapeutic Ultrasound device was used to induce mild hyperthermia in a single (region of) a target liver tumour. |
| DIAGNOSTIC_TEST | Pre-LTLD Biopsy of Target Liver Tumour | |
| DIAGNOSTIC_TEST | Post-LTLD Biopsy of Target Liver Tumour | |
| DIAGNOSTIC_TEST | Post-LTLD+FUS (Post-FUS) Biopsy of Target Liver Tumour | |
| DEVICE | Thermometry of Target Tumour | A clinically approved thermistor or thermocouple was placed in the target liver tumour for real-time thermometry. |
Timeline
- Start date
- 2014-07-01
- Primary completion
- 2017-03-01
- Completion
- 2017-04-01
- First posted
- 2014-07-03
- Last updated
- 2019-07-22
- Results posted
- 2019-06-24
Locations
1 site across 1 country: United Kingdom
Source: ClinicalTrials.gov record NCT02181075. Inclusion in this directory is not an endorsement.