Clinical Trials Directory

Trials / Completed

CompletedNCT02135094

Low Intensity Ultrasound Therapy for Upper Back Pain Relief

Short Term Effects of Long Duration Low Intensity Continuous Ultrasound for Trapezius Muscle Pain

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
33 (actual)
Sponsor
ZetrOZ, Inc. · Industry
Sex
All
Age
18 Years – 65 Years
Healthy volunteers
Not accepted

Summary

The purpose of this study is to measure the effectiveness of a wearable therapeutic ultrasound device for relief of pain associated with the trapezius muscle of the upper back over a 4-week period. The trapezius muscle is a wide, flat, superficial muscle that covers most of the upper back and the posterior of the neck.The hypothesis is that the ultrasound device will lower the reported daily pain level of subjects suffering from trapezius muscle pain in their upper back. Subjects who participate in the study will self-administer the ultrasound device daily if pain is rated 3.0 or higher on the numeric rating scale (0-10). Subjects will be required to visit the clinical site at enrollment and weeks 2 and 4 for a total of 3 visits. Subjects will report their daily pain levels in a diary. Subject will also report pain levels at 30 min, 2 hours, and 4 hours (treatment completion) after start of each treatment. The wearable ultrasound device, Sam®, has been cleared by the FDA for pain relief, relief of joint contracture, relief of muscle spasm, and increased circulation.

Detailed description

The study will have approximately 33 subjects randomly assigned into a user group (active ultrasound device) of 25 participants or a control group (inactive ultrasound device) of 8 participants with an equal number of males and females in each group. The research coordinator will be blinded to the assignment of devices to each group. The daily pain scores reported by patients who receive active devices will be compared to those who receive placebo devices. Background: Approximately 50 to 80 million people in the United States suffer from some form of chronic pain. Back pain is the most common neurological disorder in the United States after headaches and costs consumers nearly $50 billion annually. Pharmaceuticals currently dominate the treatment options despite a myriad of public health problems including cost, untoward side effects, and addiction to widely available opioid analgesics. Non-pharmaceutical treatments, such as the one under test, provide a safer and potentially lower cost alternative to traditional analgesic use.

Conditions

Interventions

TypeNameDescription
DEVICEActive ultrasound therapy devicelow intensity continuous therapeutic ultrasound at 3 megahertz (MHz) frequency and 0.132 Watts/cm2 for treatment duration of 4 hours per day
DEVICEPlacebo ultrasound therapy deviceThe placebo device appears and operates identically to the active device except that it does not emit ultrasound.

Timeline

Start date
2014-06-01
Primary completion
2015-09-01
Completion
2015-09-01
First posted
2014-05-09
Last updated
2020-04-02
Results posted
2018-06-11

Locations

1 site across 1 country: United States

Source: ClinicalTrials.gov record NCT02135094. Inclusion in this directory is not an endorsement.