Clinical Trials Directory

Trials / Completed

CompletedNCT02126852

Comparison of AMG and EMG to Avoid Residual Paralysis After General Anesthesia

Comparison of AMG (Acceleromyography) and EMG (Electromyography) to Avoid Postoperative Residual Paralysis After General Anesthesia

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
214 (actual)
Sponsor
Technical University of Munich · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

This study evaluates three different neuromuscular monitoring devices (acceleromyography, one- or three-dimensional, and electromyography) with regard to their precision to detect residual paralysis after injection of neuromuscular blocking agents and recurrence of paralysis after administration of reversal agents in a clinical setting.

Detailed description

Neuromuscular blocking agents (NMBAs) are routinely used as standard part of a modern, balanced anesthesia regime. A residual duration of action exceeding the end of surgery, also called residual neuromuscular paralysis, is a common undesired side effect and increases the risk for postoperative pulmonary complications such as aspiration or pneumonia delaying patients' discharge from the post-anesthesia care unit. To limit the incidence of residual paralysis in daily anesthesia care, quantitative neuromuscular monitoring is recommended after injection of NMBAs. If a residual effect of a NMBA is detected at the end of surgery, reversal agents such as cholinesterase inhibitors, e.g. neostigmine or a selective relaxant binding agent, e.g. sugammadex can be administered. However, if reversal agents are not adequately dosed, the risk for a residual neuromuscular blockade re-occurs. Accordingly, neuromuscular monitoring is also useful to control the action of the administered reversal agents. Although several techniques of neuromuscular monitoring are established in clinical practice, electromyography (EMG) and acceleromyography (AMG) are the most common quantitative neuromuscular monitoring devices. Electromyography, the gold standard for detecting residual neuromuscular block, is based on measuring summarized spikes of evoked muscle contractions. Acceleromyography measuring the acceleration of evoked muscle contraction is also commercially available and easy to use. This acceleration, however, can be measured both one-dimensionally and three-dimensionally. This study evaluates the three described neuromuscular monitoring devices with regard to their precision to detect residual paralysis after administration of NMBAs and recurrence of neuromuscular blockade after administration of reversal agents in a clinical setting. We plan to include and randomize a total of 200 patients. The study participants will be recruited from patients scheduled for surgery at the Klinikum rechts der Isar der Technischen Universität München, Munich, Germany. In each patient, acceleromyography (either one- or three-dimensional) will be compared with the calibrated electromyography. The findings will help to indicate which neuromuscular monitoring device is most suitable for detecting residual paralysis and recurrent neuromuscular blockade.

Conditions

Interventions

TypeNameDescription
DEVICEAcceleromyography (AMG, one-dimensionally)Neuromuscular monitoring
DEVICEAcceleromyography (AMG, three-dimensionally)Neuromuscular monitoring
DEVICEElectromyography (EMG)Neuromuscular monitoring

Timeline

Start date
2014-04-01
Primary completion
2016-04-01
Completion
2016-04-01
First posted
2014-04-30
Last updated
2016-04-28

Locations

2 sites across 1 country: Germany

Source: ClinicalTrials.gov record NCT02126852. Inclusion in this directory is not an endorsement.