Clinical Trials Directory

Trials / Completed

CompletedNCT02100488

Improving Postprandial Glycaemia by a New Developed Closed-loop Control System - Closedloop4meals

Improving Postprandial Glycaemia by a New Developed Closed-loop Control System (Closedloop4meals). An Interdisciplinary, Investigator's Initiated Project for Optimization of Glucose Control in Type1 Diabetic Subjects

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
20 (actual)
Sponsor
Fundación para la Investigación del Hospital Clínico de Valencia · Academic / Other
Sex
All
Age
18 Years – 60 Years
Healthy volunteers
Not accepted

Summary

Achieving near-normoglycemia has been established as the main objective for most patients with diabetes. However, postprandial glucose control is a challenging issue in everyday diabetes care. Indeed, excessive postprandial glucose excursions are the major contributors to plasma glucose (PG) variability in subjects with type 1 diabetes (T1DM). In addition, the poor reproducibility of postprandial glucose response is burdensome for patients and healthcare professionals. Automatic glucose control, the so-called artificial pancreas or closed-loop system, may represent the ideal solution for reaching the therapeutic goals in diabetic patients. Intuitively, closed-loop insulin delivery may be superior to open-loop insulin delivery due to a better compensation of the variability of subcutaneous insulin absorption and the intra-subject insulin sensitivity. However, several challenges exist to effectively realize an optimal postprandial closed-loop control of blood glucose. Indeed, the eating process induces one of the major glucose perturbations that need to be controlled by an artificial pancreas and is currently one of the main challenges found in clinical validations of the few existing prototypes of an artificial pancreas. In particular, experiments carried out with the currently used algorithms for glucose control (the so called PID and MPC) showed that closed-loop insulin delivery often tend to overcorrect hyperglycemia thus increasing the risk hypoglycemia. In this project, a rigorous clinical testing of a novel closed-loop controller ('artificial pancreas') will be carried out in T1DM patients treated with continuous subcutaneous insulin infusion (CSII). The innovative element of the controller is a safety auxiliary feedback based on sliding mode reference conditioning (SMRC), which has been demonstrated (in simulation studies) to limit over-insulinization and the resulting hypoglycemia, reducing glycaemic variability. Standardized meal test studies will be performed in T1DM subjects treated with CSII, comparing the administration of a classical bolus (open-loop study) with a controller-driven prandial insulin delivery (closed-loop study) based on continuous subcutaneous glucose monitoring (CGM). The hypothesis is that closed loop control will provide better postprandial control, especially in terms of reduction of glucose variability and incidence of hypoglycemia.

Conditions

Interventions

TypeNameDescription
DEVICEClosed-loop insulin infusion systemEach subject will undergo two "Open-loop" and two "Closed-loop" meal tests, each one at 1-2 week intervals, thus completing the 4 experiments in about 6 weeks. The day of the experiment, a standard mixed meal test containing 60 g of carbohydrates (CHO), will be administered. On two occasions, patients will receive in a randomized order the standard insulin bolus based on the individual insulin to CHO ratio (First arm, Open-loop study). On the other two occasions they will receive a Sliding Mode Reference Conditioning (SMRC) Closed-loop insulin administration, based on subcutaneous continuous glucose monitoring (Second arm, Closed-loop study). Commercial insulin infusion systems and continuous glucose monitoring devices will be used.
OTHEROpen-loop insulin infusion systemStandard subcutaneous insulin infusion based on the individual insulin to carbohydrate ratio. Commercial insulin infusion systems and continuous glucose monitoring devices will be used.

Timeline

Start date
2014-03-01
Primary completion
2015-07-01
Completion
2015-10-01
First posted
2014-04-01
Last updated
2015-11-17

Locations

2 sites across 1 country: Spain

Source: ClinicalTrials.gov record NCT02100488. Inclusion in this directory is not an endorsement.