Trials / Completed
CompletedNCT01988181
Adjusting Fluid Removal Based on Blood Volume in Hemodialysis: A Randomized Study
Blood Volume Monitoring Guided Ultrafiltration Biofeedback on Reduction of Intra-dialytic Hypotensive Episodes in Hemodialysis: A Randomized Cross Over Study
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 34 (actual)
- Sponsor
- University of Calgary · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
As kidney function declines, the ability to maintain water balance is impaired and is most often treated with hemodialysis. The removal of excess water in hemodialysis often leads to a sudden drop of blood pressure and causes symptoms of dizziness, light-headedness, cramping, and chest pain. This sudden drop in blood pressure has been linked with complications of heart attacks, strokes and even death. Research has focused on different ways to prevent dangerous drops in blood pressure during hemodialysis. One way is the use of blood volume monitoring biofeedback technology to monitor the patient's relative blood volume and automatically reduce the amount of fluid that is being removed when the blood volume is low to prevent the drop in blood pressure from occurring. This type of biofeedback device is currently available on some hemodialysis machines and while this approach appealing, it is not clear how effective this form of biofeedback is in preventing the drops in blood pressure. We plan to determine if the use of biofeedback based on the changes in the patient's blood volume will reduce the number of sudden drops in blood pressure that occur during hemodialysis. To do this, we will compare patients treated with this technology to current hemodialysis practices and follow them for important adverse outcomes. The result of interest will be the frequency of hemodialysis sessions complicated by a sudden symptomatic drop in blood pressure. We also plan to monitor the amount of water in the different body compartments, blood pressure, blood pressure medication use, markers of heart function, and patient symptoms and quality of life. We hope that by providing information on this technology we can reduce the sudden drops in blood pressure in hemodialysis, the associated rates of serious disease or death, and improve patient quality of life.
Detailed description
This is a 22 week parallel group, randomized crossover trial to determine the effect of blood volume monitoring, BVM, guided ultrafiltration (UF) biofeedback on symptomatic intradialytic hypotension (IDH) episodes amongst IDH prone patients. The first part of the study (Part 1 - Run-In/Dialysis Optimization Phase), eligible patients will undergo a four-week run-in phase. During this period all patients will undergo a comprehensive clinical assessment including, clinical weight assessment, anti-hypertensive medication review, and dialysis prescription standardization. At the end of the run-in phase, patients that still meet eligibility criteria will enter the randomized cross-over phase. In part 2 (Randomized Cross-Over Phase), patients are randomized to regular best clinical practice hemodialysis, HD (without BVM-guided UF biofeedback; control arm) or to BVM-guided UF biofeedback (intervention arm) for an 8 week period. This will be followed by a two-week washout phase and then patients will be crossed over for a second 8-week phase. The study will be conducted and reported following the Consolidated Standards of Reporting Trials (CONSORT) 2010 guidelines.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | BVM-UF biofeedback | The Fresenius 5008 uses an ultrasound and temperature monitor incorporated into the machine to detect ultrasonic velocity and temperature changes to derive the total protein concentration, which is a sum of total plasma proteins and hemoglobin. The relative blood volume is calculated at by dividing the initial concentration of total protein by the total protein concentration at any given time, multiplied by 100. The HD software is based on the critical blood volume entered at the beginning of the dialysis session for each individual patient. The UF rate is adjusted based on the changes in the relative blood volume to the patient's critical relative blood volume. |
| DEVICE | Fresenius 5008 HD machine (Fresenius Medical Care, Bad Homburg, Germany) | For an 8-week period, patients in the best clinical practice (control) phase will use their same prescription as the run-in phase, dialysate sodium of 138mmol/L, dialysate calcium of 1.25mmol/L, dialysate temperature of 36oC, and constant UF rate. BVM will be disabled in this group. |
Timeline
- Start date
- 2014-06-01
- Primary completion
- 2015-06-01
- Completion
- 2015-06-01
- First posted
- 2013-11-20
- Last updated
- 2015-07-27
Locations
1 site across 1 country: Canada