Clinical Trials Directory

Trials / Completed

CompletedNCT01943253

Water-jet Assisted ESD vs Conventional ESD Technique for Treating Early Gastric Cancer

Water-jet Assisted Endoscopic Submucosal Dissection (ESD) in Comparison to Conventional ESD Technique for Treatment of Early Gastric Cancer

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
117 (actual)
Sponsor
Shanghai Zhongshan Hospital · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

1. Introduction The aim of the study is to evaluate the efficacy and safety of ESD by use of a new water-jet assisted ESD system using the HybridKnife® in patients with early gastric neoplastic lesions in comparison to the conventional ESD established in Japan. The water-assisted ESD technology allows pressure controlled injection of fluids through the tip of a recently developed HybridKnife®. Submucosal injection, circumferential cutting and dissection of lesions as well as coagulation of bleeding can be performed with the same device without need for changing the instrument. These options should accelerate the procedure and may increase its safety and efficacy. 2. Hypothesis The water-jet assisted ESD technique using the HybridKnife® bears the advantage of less instrument changes due to the combination of high-frequency cutting and water-jet application in one single instrument. This should lead to a simplified ESD procedure, shorter learn-ing curve and especially to a shorter procedure time. The water-jet assisted ESD technique should be shorter than the conventional ESD techniques using IT2-, Dual- and Hook-Knifes at least with the same safety and effectiveness.

Conditions

Interventions

TypeNameDescription
DEVICEConventional ESDConventional ESD: Conventional ESD technique using IT2-Knife, Dual-Knife, Hook-Knife (Olympus Europe, Hamburg, Germany; Olympus Japan) ERBE VIO 300D (V2.1.4) RF-surgery system (ERBE Elektromedizin GmbH, Tübingen, Germany) Injection of fluid: Syringe
DEVICEHybridknife ESDGroup 2: Water-jet assisted HybridKnife® ESD technique using HybridKnife® (Erbe Elektromedizin GmbH, Tübingen, Germany) ERBE VIO 300D (V2.1.4) RF-surgery system (ERBE Elektromedizin GmbH, Tübingen, Germany) Injection of fluid: Integrated in HybridKnife® with ERBEJet 2 water-jet surgery system (ERBE Elektromedizin GmbH, Tübingen, Germany)

Timeline

Start date
2011-05-01
Primary completion
2012-07-01
Completion
2012-10-01
First posted
2013-09-16
Last updated
2013-09-16

Locations

1 site across 1 country: Germany

Source: ClinicalTrials.gov record NCT01943253. Inclusion in this directory is not an endorsement.