Summary

Saline infusion sonohysterography and other intrauterine investigations methods may cause uterine cramping, pain and vasovagal reactions. According to few of previous studies the position of catheter placement can affect the magnitude of pain and amount of saline required during the sonohysterography. The purpose of this double blind control trial study is to assess whether the location of the balloon catheter either the uterus or cervix during sonohysterography can affect the magnitude of pain and the rate of vasovagal reaction.

Detailed description

The proposal of study approved by the investigators institutional review boards and institution's ethical committee, and all participants will sign a written consent before enter to study. A total of 300 infertile women undergoing sonohysterography will be randomized to intrauterine or intracervical balloon catheter placement. The examination is scheduled in the early follicular phase of menstrual cycle, immediately after cessation of menstrual flow and before day 10. After preparation of patient, a 2 lumen 6-French flexible catheter is introduced into the cervical canal and balloon at the catheter tip is placed in the lower uterine segment or 1 cm into cervical canal and inflated with 1 mL of sterile saline solution. Under sonographic guidance, sterile normal saline solution (10-50 mL) is slowly introduced into the cavity until an adequate distention of the uterine cavity is obtained. Three-dimensional ultrasound scanned volumes are recorded. Patients are asked to assess their level of pain at the time of the balloon inflation and deflation using a 10-point visual analog pain scale. Patients are checked for the sign and symptoms of vasovagal reaction during and 30 minutes after procedure. Outcome measures will be assessed based on the intent-to-treat principle.

Conditions

Interventions

TypeNameDescription
DEVICEsonohysterography with inflated catheter in uterine cavityduring the procedure of sonohysterography balloon catheter is inflated in the uterine cavity
DEVICEsonohysterography with inflated catheter in cervical cavityDuring the procedure of sonohysterography balloon catheter is inflated in the cervical canal

Timeline

Start date
2012-05-01
Primary completion
2013-09-01
Completion
2013-10-01
First posted
2013-09-05
Last updated
2014-05-06

Locations

1 site across 1 country: Iran

Source: ClinicalTrials.gov record NCT01936116. Inclusion in this directory is not an endorsement.