Clinical Trials Directory

Trials / Terminated

TerminatedNCT01918605

Protection of Rectum From High Radiation Doses Using a Spacer

Protection of Rectum From High Radiation Doses During Prostate Cancer Low-dose Brachytherapy Using Diluted or Non-diluted DuraSeal as a Spacer

Status
Terminated
Phase
N/A
Study type
Interventional
Enrollment
5 (actual)
Sponsor
University of Oulu · Academic / Other
Sex
Male
Age
50 Years – 78 Years
Healthy volunteers
Not accepted

Summary

The purpose of this study is to evaluate the usefulness of diluted and non-diluted DuraSeal product as a spacer between prostate and rectum in prostate cancer low-dose brachytherapy.

Detailed description

Radiation therapy for prostate cancer leads to inappropriate radiation dose to the rectum wall leading rectum adverse effects in long term for some patients. A resorbable spaces between prostate and rectum could decrease the incidence of these side effect. In this trial, men with prostate cancer with intention to curative treatment by low-dose brachytherapy will be recruited. The subjects will be randomized to receive either diluted or non-diluted DuraSeal product as a spacer between prostate and rectum. Diluted or non-diluted DuraSeal will be applied between rectum and prostate at the end of the brachytherapy seed implantation procedure. After the implantation of the brachytherapy seeds, a needle is placed between rectum and prostate through perineal skin under transrectal ultrasound guidance. The proper position of the needle is confirmed by the injection of 10-15 ml sterile saline solution. After that, DuraSeal components are diluted in 1:1 with sterile saline and 6-10 ml of this diluted product will be injected using DuraSeal applicator. If the subject is randomized to receive non-diluted DuraSeal, the procedure will be identical with the exception the DuraSeal components will not be diluted. The resolution of the spacer will be followed by repeated plain computer tomography (CT) of pelvis performed a day before operation, a day after the operation, and 4, 8 and 12 weeks after the operation. In addition, magnetic resonance imaging of pelvis performed 12 weeks after the operation. The space created between prostate and rectum will be documented by plain CT and magnetic resonance imaging. Rectum radiation dose will be calculated based on these scans. Time to DuraSeal resolution will be evaluated from the scans. Possible side effects will be collected by subject interviews during follow-up visits at 4, 8 and 12 weeks after the operation.

Conditions

Interventions

TypeNameDescription
DEVICEDiluted spacer
DEVICENon-diluted spacer

Timeline

Start date
2013-06-01
Primary completion
2017-10-01
Completion
2017-10-01
First posted
2013-08-08
Last updated
2017-10-27

Locations

1 site across 1 country: Finland

Source: ClinicalTrials.gov record NCT01918605. Inclusion in this directory is not an endorsement.