Trials / Completed
CompletedNCT01894906
Quantitative Mass Transfer of SFP-iron From Dialysate to Blood in CKD-HD Patients
A Controlled, Randomized Study to Assess the Quantitative Mass Transfer of Iron From SFP-containing Hemodialysate Under Varying Conditions of Blood and Dialysate Flow Rates, Dialyzer Membrane Types and Dialysate Bicarbonate Concentrations in CKD-HD Patients.
- Status
- Completed
- Phase
- Phase 1 / Phase 2
- Study type
- Interventional
- Enrollment
- 12 (actual)
- Sponsor
- Rockwell Medical Technologies, Inc. · Industry
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
The purpose of this study is to determine the quantity of iron derived from SFP that is transferred from the dialysate to patients during a single dialysis session. The effects of various conditions which may affect the transfer of iron such as blood and dialysate flow rate, changes in bicarbonate delivery, dialyzer membrane type and the effect of reuse will also be investigated. The absorption and removal of iron from the blood will also be investigated.
Detailed description
* A total of 12 subjects on standard 3X/week hemodialysis will be studied in 2 groups (6 subjects per group) * 2 primary dialyzer membranes will be studied.: * Polyamide Membrane (Gambro Polyflux series: 17R and 21R) * Cellulose Triacetate (Baxter CT series: CT-190) * Each 1-week treatment cycle will include 3 haemodialysis (HD) sessions per subject, including 2 study treatment-HD sessions and 1 non-treatment-HD session per subject. Treatment-HD sessions will be conducted midweek and end-of-week (i.e. Dialysis days 3 and 5 of each week with a 1 day interdialytic interval) to avoid excessive fluid shifts due to the increased UF needed during the non-treatment HD session (conducted at beginning of the week; HD day 1). * Within each group, each subject will be randomized to 1 of 6 treatment sequences. The treatments to be investigated are: Control; new dialyzer, reused dialyzer, low blood flow/dialysate flow, Low bicarbonate concentration and a different synthetic dialyzer membrane (PAES) * Blood for a complete serum iron profile over time will be obtained during the new dialyzer (SFP/standard bicarbonate/new dialyzer/ high Qb and Qd) for all subjects. This will necessitate approximately a 24-hour inpatient confinement to obtain blood at specified time intervals after dialysis is completed. Blood for a partial iron profile will be collected during the dialysis sessions at all other dialysis sessions. * Each of the 6 enrolled subjects per dialyzer membrane type will be assigned to a different sequence of treatments to help ensure that the treatment sequence does not affect the analysis (Note: the first dialysis sessions of each of the 3 study weeks, i.e. HD1, HD4 and HD7, are non-study related sessions during which no study procedures are performed except for adverse event collection. * Patients should not be receiving any of the following medications from screening through the end of the study: * Oral iron preparations, including multivitamin supplements containing iron * Intravenous iron preparations * Doses of ESA's should not be changed from screening to the end of the study.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DRUG | Soluble Ferric Pyrophosphate | |
| OTHER | Placebo |
Timeline
- Start date
- 2013-07-01
- Primary completion
- 2013-09-01
- Completion
- 2013-09-01
- First posted
- 2013-07-10
- Last updated
- 2015-02-16
- Results posted
- 2015-01-09
Locations
1 site across 1 country: United States
Source: ClinicalTrials.gov record NCT01894906. Inclusion in this directory is not an endorsement.