Clinical Trials Directory

Trials / Completed

CompletedNCT01889524

Radioaerossol Pulmonary Deposition Using Mesh in Normal Subjects

RADIOAEROSSOL PULMONARY DEPOSiTION USING MESH AND JET NEBULIZERS DURING NONINVASIVE VENTILATION IN NORMAL SUBJECTS: A RANDOMIZED CROSSOVER CLINICAL TRIAL

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
10 (actual)
Sponsor
Universidade Federal de Pernambuco · Academic / Other
Sex
All
Age
18 Years – 60 Years
Healthy volunteers
Accepted

Summary

In vivo deposition studies of aerosol administration during noninvasive ventilation are scarce in the current literature. We assessed 10 normal subjects in a crossover study evaluated by pulmonary scintigraphy aiming to compare radiaoaerosol pulmonary index and radioaerosol mass balance in the different compartments (pulmonary and extrapulmonary) of radiotagged aerosol administered using vibrating mesh nebulizers (VMN) and conventional jet nebulizer (JN) during noninvasive ventilation (NIV).

Conditions

Interventions

TypeNameDescription
OTHERMesh nebulizerVMN (NIVO, Respironics®, Murrysville, Pennsylvania, USA) with an MMAD of 3.0 µm was placed in the elbow adapter at the mask. Inhalation was performed using diethilene triamine penta-acetic technetium (99mTc-DTPA) with radioactivity of 25 millicuries (Nobre et al., 2007). Both nebulizers were charged with 2.5 mg of salbutamol and 0.25 mg of ipratropium bromide and normal saline solution to complete a fill volume of 3 mL.
OTHERJet nebulizerThe JN (Misty Max, Air Life, Yorba Linda, USA) with a particle MMAD of 5 µm (according to the manufacturer information) was positioned in the circuit using a "T" piece placed between the circuit leak and the mask, and operated with oxygen flow at 8 L/min. Inhalation was performed using diethilene triamine penta-acetic technetium (99mTc-DTPA) with radioactivity of 25 millicuries (Nobre et al., 2007). Both nebulizers were charged with 2.5 mg of salbutamol and 0.25 mg of ipratropium bromide and normal saline solution to complete a fill volume of 3 mL.
OTHERNoninvasive ventilation-NIVBilevel positive airway pressure (BiPAP Synchrony, Respironics®, Murrysville, Pennsylvania, USA) was applied through face mask (Comfort Full 2, Respironics®, Murrysville, Pennsylvania, USA) attached with straps and pressure adjusted to12 cmH2O peak inspiratory pressure and 5 cmH2O of expiratory pressure at the beginning of the procedure. Patients were adapted to use NIV before starting measurements, pressures were titrated before reaching the established levels and just after this period masks were fitted using the straps. They were oriented to use a breathing pattern inspiring deeply and exhaling slowing to avoid ventilator-patient asynchrony.

Timeline

Start date
2012-01-01
Primary completion
2012-01-01
Completion
2012-04-01
First posted
2013-06-28
Last updated
2013-06-28

Locations

1 site across 1 country: Brazil

Source: ClinicalTrials.gov record NCT01889524. Inclusion in this directory is not an endorsement.