Study of Effectiveness of Smaller Gauge Fenestrated Catheters for Use in IV Contrast Enhanced CT Scans

A Randomized Controlled Study to Determine Whether Smaller Gauge Fenestrated Catheters Are as Effective as Larger Gauge Non-fenestrated Catheters for Use in IV Contrast Enhanced CT Scans

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
238 (actual)
Sponsor
Becton, Dickinson and Company · Industry
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The purpose of this study is to compare multidetector computed tomography (CT) image quality following peripheral venous high pressure injection of iodinated intravenous contrast media between a 20 gauge (GA) fenestrated, intravenous catheter (BD Nexiva™ Diffusics™) and an 18 GA non-fenestrated, intravenous catheter. In the contrast enhanced CT procedure (CECT), a machine (power injector) is used to rapidly deliver contrast agent to an individual's circulatory system. The contrast allows for greater differentiation of tissues in images of the area of interest, affording a better opportunity to visually assess the area and hence make a more accurate diagnosis. CECT often requires a high rate of contrast flow (≥ 5 mL/sec) through the IV catheter to provide sufficient contrast for an acceptable image. Typically an 18 GA IV catheter is required to achieve these high flow rates; however, often the patient does not have a vein that will accommodate this large size catheter. The BD Nexiva™ Diffusics™ IV catheter is designed to deliver a higher flow rate than a conventional catheter of the same gauge by incorporating fenestrations (small openings) near the tip of the catheter that allow fluid to exit the catheter in addition to that which normally exits through the main opening at the tip of the catheter.

Detailed description

This is a prospective study performed in adult human subjects who have been referred for a CECT. The study will occur during a single visit. Once consented and enrolled, subjects whose antecubital veins can accommodate an 18 GA IV catheter (as assessed by the Inserter or designee of the PI), will be randomized to receive either a conventional 18 GA IV catheter (reference, control) or a 20 GA BD Nexiva™ Diffusics™ IV catheter (test). Subjects whose veins are not considered suitable for an 18 GA IV catheter will be placed in a non-randomized cohort for placement of a 20 GA BD Nexiva™ Diffusics™ IV catheter. Subjects will receive one (1) catheter for the study. The primary objective of this study is to compare multidetector computed tomography (CT) image quality following peripheral venous high pressure injection of iodinated intravenous contrast media between a 20 GA fenestrated, intravenous catheter (BD Nexiva™ Diffusics™) and an 18 GA non-fenestrated, intravenous catheter. The 20 GA BD Nexiva™ Diffusics™ IV catheter will be considered non-inferior to conventional 18 GA IV catheters if the 95% upper bound for the difference in percentage of images of acceptable quality between the images acquired using the 18 GA IV catheters and the 20 GA BD Nexiva™ Diffusics™ IV catheters is less than 15%. Study catheters will be inserted by appropriately licensed healthcare professionals (Inserters). Prior to enrollment, potential Inserters will be trained and qualified by the Sponsor on proper use of the BD Nexiva™ Diffusics™ IV catheter in both an artificial hand model and then in human patients. Inserters will then be expected to use the test product for a period of two (2) weeks, in order to gain familiarity with the product. Because BD Nexiva™ Diffusics™ IV catheters are not currently used in the Johns Hopkins Outpatient Center, the Sponsor will provide BD Nexiva™ Diffusics™ IV catheters for use during this training and familiarization period.

Conditions

Interventions

TypeNameDescription
DEVICE20GA BD Nexiva DiffusicsThe Inserter will have a single attempt on each arm (antecubital area) in which to insert the study catheter. If the catheter is not successfully inserted on the first attempt, the Inserter may make a second attempt in the contralateral arm. If the Inserter is unsuccessful in the second attempt, the subject is to be discontinued from the Study, and additional (non-Study) insertion attempts may be made according to facility policies.
DEVICE18GA Conventional CatheterThe Inserter will have a single attempt on each arm (antecubital area) in which to insert the study catheter. If the catheter is not successfully inserted on the first attempt, the Inserter may make a second attempt in the contralateral arm. If after the first attempt, there is no vein in the contralateral arm that can accommodate an 18 gauge catheter, the subject is to be discontinued from the Study, and additional (non-Study) insertion attempts may be made according to facility policies.

Timeline

Start date
2013-01-01
Primary completion
2013-02-01
Completion
2013-02-01
First posted
2013-01-21
Last updated
2014-05-02
Results posted
2014-03-26

Locations

1 site across 1 country: United States