Summary

Endoscopic ultrasound (EUS) is paramount in the diagnosis and evaluation of cancers involving the gastrointestinal tract. EUS allows for the acquisition of cellular (fine needle aspirate - FNA) or tissue biopsy (fine needle biopsy - FNB) for diagnostic purposes. This has traditionally been done with fine needle aspirate where a needle is inserted into the tumor and potentially malignant cells are extracted for microscopic analysis. More recently, a needle that allows a tissue biopsy for histologic analysis has been FDA approved. The Echotip Procore (Cook Medical) core biopsy needle (ETP), has been demonstrated to provide excellent efficacy for core biopsy samples. Final diagnostic yield using this needle ranges from 80-90% and appears to be significantly greater than EUS-FNA for lesions requiring histology for diagnosis. However, there is currently only limited data from prospective studies comparing EUS-FNA to EUS-FNB with the ETP needle. The investigators propose a randomized, prospective, cross-over study comparing diagnostic accuracy of EUS-FNA to EUS-FNB.

Detailed description

Endoscopic ultrasound (EUS) is paramount in the diagnosis and evaluation of cancers involving the gastrointestinal tract. EUS allows for the acquisition of cellular (fine needle aspirate - FNA) or tissue biopsy (fine needle biopsy - FNB) for diagnostic purposes. This has traditionally been done with fine needle aspirate where a needle is inserted into the tumor and potentially malignant cells are extracted for microscopic analysis. More recently, a needle that allows a tissue biopsy for histologic analysis has been FDA approved. We will compare tissue samples obtained by standard FNA to FNB with a sample size of 140 patients with the primary outcome being diagnostic yield. Each patient will be randomized to FNA or FNA. If after 3 passes the on-site evaluation remains inadequate, the endoscopist will crossover to the other arm.

Conditions

Interventions

TypeNameDescription
DEVICEFine needle aspirationFine needle aspiration
DEVICEFine needle biopsyFNB

Timeline

Start date
2012-09-01
Primary completion
2014-02-01
Completion
2014-02-01
First posted
2013-01-16
Last updated
2018-01-18
Results posted
2015-03-18

Locations

3 sites across 1 country: United States

Source: ClinicalTrials.gov record NCT01769248. Inclusion in this directory is not an endorsement.