Trials / Completed
CompletedNCT01763775
Clinical Trial of Transtek Body Fat Analyzer (GBF-1251-B & Other 3 Models)
Verify the Functions and Efficiency of Transtek (Trade Mark) Body Fat Analyzer, GBF-1251-B, BF-1255-B, BF-1256-B, and GBF-1257-B
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 50 (actual)
- Sponsor
- Leo Wang · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Accepted
Summary
The clinical protocol of the clinical testing of this device: 1. Objective of the test: To verify the functions and efficiency of devices. 2. Test methods and procedures: Comparison Test. 3. Device Under Test (DUT): Transtek Body Fat Analyzer, Model: GBF-1251-B, BF-1255-B, BF-1256-B, and GBF-1257-B. 4. Comparison device: Transtek, Glass Body Fat Analyzer, GBF-950-D. 5. Study endpoints: DUT and the comparison device are substantial equivalence. 6. Statistical methodology used: Description of statistical methods.
Detailed description
1. Test Purpose: The aim of clinical test is to collect weight, body fat, total body water, bone mass, and muscle mass reading value which measured by DUT and reference device. 2. Target Subject: The subject database shall contain at least 25 male and 25 female subjects and all above 18 years old. 3. Test procedures: 1. Record the name, age, gender, and height of each subject. 2. Let subject seated calmly for two minutes before test, dry the feet. 3. Use device to measure weight, body fat, total body water, bone mass, and muscle mass; record reading value. 4. For each subject, repeat 3) to get 3 pairs measurements. 5. Repeat step 1) to 4) for every device (DUT: GBF-1251-B, BF-1255-B, BF-1256-B, and GBF-1257-B; and reference device: GBF-950-D). 6. Repeat step 1) to 5) for each subject. 4. Note: 1. No motion and speaking are allowed during the measurement. 2. All DUT use the same algorithms and contact the patient at the same body locations (feet), and operate on the same frequency. 3. Test environment: Temperature: 22±1℃; Relative humidity: 40\~70%.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Transtek 125X | Measuring weight, total body water, body fat, muscle mass, and bone mass. Measure each participants by Transtek 125X (GBF-1251-B, BF-1255-B, BF-1256-B, GBF-1257-B). |
| DEVICE | Transtek 950D | Measuring weight, total body water, body fat, muscle mass, and bone mass. Measure each participants by Transtek 950D (GBF-950-D). |
Timeline
- Start date
- 2012-10-01
- Primary completion
- 2012-10-01
- Completion
- 2012-10-01
- First posted
- 2013-01-09
- Last updated
- 2013-01-09
Locations
1 site across 1 country: China
Source: ClinicalTrials.gov record NCT01763775. Inclusion in this directory is not an endorsement.