Comparative Study of 22 and 25 Gauge ProCore EUS-guided Biopsy in Pancreatic Mass

Endoscopic Ultrasound-guided Fine Needle Tissue Acquisition With 22- and 25-gauge ProCore Needle in Solid Pancreatic and Peripancreatic Masses: A Prospective Comparative Study

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
219 (actual)
Sponsor
Samsung Medical Center · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

Background: EUS-guided fine needle aspiration (FNA) is a major diagnostic tool in the patient with pancreatic mass with high specificity, specificity and accuracy. However FNA with small needle has sometimes failed in acquisition of tissue due to small caliber. To overcome this limitation, newly designed ProCore needle was developed and flexible 22 and 25 gauge ProCore needles were frequently used. However there was no comparative study of the efficacy and accuracy between 22 and 25 gauge ProCore needle yet. Aim: To compare the efficacy and accuracy of EUS-guided FNA between 22 and 25 gauge ProCore needle. (The investigators hypothesized that the accuracy of 25 gauge Procore needle is not inferior to 22 gauge ProCore needle.)

Detailed description

Patient and methods: Patients who have pancreatic or peripancreatic mass in imaging studies which need pathologic confirm. These patients were randomly assigned to 22 gauge or 25 gauge group. Procedure: They underwent EUS-guided FNA, 3 times with 10 times of to-and pro movement each. The number of patients required: We used confidence intervals (CIs) with a prespecified non-inferiority margin of 10% for the non-inferiority analysis. We concluded non-inferiority of PC25 to PC22 if the lower limit of the 95% CI for the difference (PC25-PC22) was not lower than -10%. It was assumed that the diagnostic accuracy of one pass was 75% and that of three cumulative passes was estimated to be 98.4% in PC22. Based on these assumptions, the calculated sample size was 216 samples with power of 80% and significance level of 5%.

Conditions

Interventions

TypeNameDescription
DEVICE22 gauge ProCore needle biopsy22 gauge, EchoTip® ProCore™ High Definition Ultrasound Biopsy Needle
DEVICE25 gauge ProCore needle biopsy25 gauge, EchoTip® ProCore™ High Definition Ultrasound Biopsy Needle

Timeline

Start date
2013-01-01
Primary completion
2014-12-01
Completion
2015-11-01
First posted
2012-11-16
Last updated
2016-04-28

Locations

1 site across 1 country: South Korea

Source: ClinicalTrials.gov record NCT01727921. Inclusion in this directory is not an endorsement.