Noninvasive Monitoring of Vital Signs in Neonates
- Status
- Unknown
- Phase
- Phase 2
- Study type
- Interventional
- Enrollment
- 100 (estimated)
- Sponsor
- Meir Medical Center · Academic / Other
- Sex
- All
- Age
- 1 Day – 6 Months
- Healthy volunteers
- Not accepted
Summary
the investigators are assessing a non-invasive monitor based on dynamic light scattering that measures pulse rate and respiration rate. The monitor also will be equipped with a temperature sensor and a motion sensor. This monitor will allow multi-parametric measurements in neonates in a simple and noninvasive manner.
Detailed description
Monitoring vital signs in neonates is important. This currently is done with multiple standard clinical monitors. the investigators are developing a very small (coin-sized) sensor that can measure pulse rate, respiratory rate, temperature and body motion. the investigators propose to test our sensor against standard monitoring techniques in neonates in a neonatal ICU (NICU). The monitor, called ELFI-monitor, is based on dynamic light scattering. A low-power laser beams light into the skin, and the red blood cells in the underlying skin return the light which is recorded in a light sensor. The movement of the red blood cells is affected by the rhythmic cardiac contractility. in this manner, heart rate and rhythm can be assessed. The ELFI monitor also contains an embedded temperature probe and a miniature 3-D motion sensor, allowing capture of additional parameters. Methods: the investigators plan to study 100 neonates admitted to the NICU of Meir Hospital Center. These infants are routinely monitored with standard equipment including ECG, oximeter, temperature, and respiratory monitors. the investigators will simultaneously monitor these children with the ELFI monitor, recording pulse rate, cardiac rhythm, respiratory rate, skin temperature and body motion. Recordings will be conducted for a one-hour period on each subject. Data recordings from the ELFI sensor will be compared to the readouts of the conventional monitors used on the patient. It is important to emphasize that the data recordings of the ELFI sensor will not affect clinical decisions in any manner, but will merely be recorded for comparison with conventional sensors.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | The new sensor is not on the market. We have named it Elfi-sensor. | Participating subjects will be monitored for one hour with a noninvasive sensor.The noninvasive sensor, the size of a penny, will be affixed to the skin, above the umbilicus, with pediatric adhesive tape. The monitor will record continuously the heart rate, cardiac rhythm, respiratory rate and body motion. |
Timeline
- Start date
- 2013-05-01
- Primary completion
- 2014-10-01
- First posted
- 2012-10-16
- Last updated
- 2013-02-12
Locations
1 site across 1 country: Israel