CompletedNCT01705041

Preliminary Evaluation of a Point-Of-Care Liver Function Test

Preliminary Field Evaluation of a Point-of-Care Transaminase Test

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
700 (actual)
Sponsor
PATH · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The proposed preliminary field evaluation will compare a point-of-care (POC) transaminase test with the standard of care test used in an HIV clinic at the Hospital for Tropical Diseases in Ho Chi Minh City, Vietnam.

Detailed description

The DFA transaminase test provides rapid categorical measurement of ALT in a whole blood specimen taken via finger-stick. The test is based on the platform technology of "paper microfluidics" (also known as "patterned paper"), in which hydrophobic barriers are patterned into a sheet of paper in order to create microfluidic, hydrophilic paths within the paper, through which flow can be directed towards specific detection zones. The test is designed for visual color-coded readout in three ALT ranges ("bins") that correspond to the ranges of AST and ALT (\<3x the upper limit of normal (ULN), 3-5x ULN, and \>5x ULN) currently used for clinical management decisions per US TB and HIV treatment guidelines. The bin cutoffs are common to treatment guidelines used around the globe, including those used by the Vietnam Ministry of Health. The colorimetric readout is designed to be read by eye using a visual "read guide" allowing the reader to make a semi-quantitative estimate or assign a categorical value into one of three bins. Alternatively, if the device is scanned (e.g. desk-top scanner) or photographed (e.g. cell phone or standard digital camera, see (9)) and read with image-analysis software, it should be possible to generate a quantitative result. Additionally, multiple control zones notify the user of insufficient sample volume, hemolysis, or damaged reagents. The overall goal of this study is to conduct a preliminary field evaluation of an investigational transaminase test in a population at risk for DILI. The primary objectives are: 1. Determine device accuracy by measuring the percent agreement of the categorical visual readout DFA transaminase test and the standard of care tests used in the HTD HIV clinic. 2. Determine inter-operator variability. 3. Determine device failure rate as defined by invalid test results.

Conditions

Interventions

TypeNameDescription
DEVICEDiagnostics for All liver function test (LFT)HIV clinic patients meeting targeted enrollment criteria will give fingerstick blood for use on investigational LFT in comparison to routine transaminase test performed at the clinic lab (gold standard)

Timeline

Start date
2012-06-01
Primary completion
2012-08-01
Completion
2012-12-01
First posted
2012-10-12
Last updated
2013-01-31

Locations

1 site across 1 country: Vietnam