Clinical Trials Directory

Trials / Completed

CompletedNCT01704118

Comparison of Size 1 I-gel and ProSeal Laryngeal Mask

Is Size 1 I-gel More Effective Than Size 1 ProSeal Laryngeal Mask for Anesthetized Infants and Neonates?

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
50 (actual)
Sponsor
Inonu University · Academic / Other
Sex
All
Age
6 Months
Healthy volunteers
Not accepted

Summary

Objective of this prospective, randomized and controlled study is to compare the performances of recently-released size 1 I-gel and size 1 PLMA proven to be superior to classical LMA with prospective studies. In this study, primer endpoint was value of airway leak pressure and secondary insertion time, insertion success and conditions, initial airway quality, hemodynamic parameters, fiberoptic view and complications will be assessed.

Detailed description

Routine monitorization will be performed. Lidocaine 1 mg.kg-1, remifentanil 1 mcg.kg-1 (slow bolus in approximately 1 minute) and 3 mg.kg-1 propofol will be administered in anaesthesia induction. In Group P, PLMA with fully deflated cuff and applied water-based lubricant, will be inserted using a metal introducer. After insertion, cuff will be inflated with a recommended volume of air and then cuff pressure will be adjusted to 60 cm H2O with manometer. In Group I, I-gel with its cuff lubricated will be orally inserted along the hard palate until resistance will be felt, as recommended by the manufacturer. The time between picking up the prepared PLMA (with introducer and deflated cuff) or I-gel and the appearance of the first stable capnographic trace will be recorded as the insertion time. The conditions for insertion will be ere scored according to mouth (1: full, 2: partial, 3: nil), gagging or coughing (1: nil, 2: slight, 3: gross), swallowing (1: nil, 2: slight, 3: gross), head or limb movement (1: nil, 2: slight, 3: gross), laryngospasm (1: nil, 2: slight, 3: complete) and ease of insertion (1: easy, 2: difficult, 3: impossible). Fresh gas flow will be adjusted to 3 L.min-1, and after closing the expiratory valve the airway pressure at which an audible leak in the mouth occurred will recorded as the 'Pleak'. When Pleak reach 35 cm H2O, expiratory valve will be opened. Anatomical position of airway device will viewed by inserting fiberoptic bronchoscope through the ventilation tube. Complications encountered during and at the end of the operation such as desaturation (sPO2 less than 90%), gastric insufflation, aspiration, laryngospasm, bronchospasm and blood stain on the airway device during removal will be recorded.

Conditions

Interventions

TypeNameDescription
DEVICEI-gelSupraglottic airway device
DEVICEProSeal Laryngeal maskSupraglottic airway device

Timeline

Start date
2012-01-01
Primary completion
2012-09-01
Completion
2012-10-01
First posted
2012-10-11
Last updated
2012-10-11

Locations

1 site across 1 country: Turkey (Türkiye)

Source: ClinicalTrials.gov record NCT01704118. Inclusion in this directory is not an endorsement.