Summary

The investigators seek to demonstrate the non-superiority of oral contrast versus no oral contrast in intravenously enhanced CT in the outpatient setting. The investigators want to decrease preparation time for the patient and decrease delay in obtaining the study which will ultimately lead to faster results and an increased level of patient convenience. The investigators hypothesis: Oral contrast does not significantly affect the diagnostic confidence of interpreting radiologists in intravenously enhanced abdominal CT scans.

Detailed description

This study will be a randomized controlled trial comparing radiologist confidence when faced with an intravenously enhanced study with and without oral contrast. At the time of making the appointment, the clerk will ask the patient if he/she wishes to participate in a research study about the impact of oral contrast. If the patient assents, he/she will receive a phone call from a research assistant to obtain informed consent. The first ten patients to call the office to schedule a scan using a 64 slice MDCT will be recruited and randomized if they consent. Subjects will be randomized at the time of recruitment, which will be when he/she calls to make the appointment for the exam, in a 1:1 ratio between the control arm (contrast) and the experimental arm (no contrast). The control arm will either pick up their two bottles of oral contrast at a radiology office or have the bottles mailed to them as is currently the standard. They will drink the oral contrast two hours before the study. They will also ingest 300 mL of water immediately prior to imaging and be administered the standard intravenous contrast dose. The experimental group will not be mailed or given any oral contrast. They will arrive at their appointment and ingest 300 mL of water immediately prior to the exam as well as the standard intravenous contrast dose and be scanned. This design will eliminate the need to repeat scanning patients, thus decreasing radiation dose. A patient satisfaction survey will be given to each patient following the exam and handed to the technologist

Conditions

Interventions

TypeNameDescription
OTHERWithhold oral contrastThe intervention is to withhold oral contrast