Clinical Trials Directory

Trials / Withdrawn

WithdrawnNCT01623726

Transcranial Direct Current Stimulation (tDCS) as Therapeutical Strategy for Negative Symptoms in Schizophrenia

Transcranial Direct Current Stimulation (tDCS) as Therapeutical Strategy for Negative Symptoms in Schizophrenia: a Double-blind Randomized Clinical Trial

Status
Withdrawn
Phase
Phase 2
Study type
Interventional
Enrollment
0 (actual)
Sponsor
University of Sao Paulo · Academic / Other
Sex
All
Age
18 Years – 59 Years
Healthy volunteers
Not accepted

Summary

The current research is aimed at using Transcranial Direct Current Stimulation (tDCS) as complementary therapeutic tool in the treatment of schizophrenia. Patients will be randomized into two groups (tDCS-active x tDCS-sham) accordingly to detailed protocol. Main outcome will be measured by specific clinical rating scales based on the assessment of negative symptoms. A total of 40 patients ought to be enrolled as specified in methodology. Secondary outcomes shall include collateral effects evaluation, anxiety and depressive scales as well as clinical monitoring.

Detailed description

Overview The present study is a double-blind randomized clinical trial in which patients should be allocated from a General Psychiatry Service into two groups (tDCS-active x tDCS-sham). Subjects who fulfilled eligibility criteria will undergo ten days of consecutive stimulation (active or sham) and will return after two to four weeks for final clinical assessment. Patients who shown no response in rating scales and that were allocated to sham intervention group will be able to choose whether or not they want to undergo the active intervention at follow up (partial cross-over)

Conditions

Interventions

TypeNameDescription
PROCEDURETranscranial Direct Current Stimulation (tDCS)Transcranial Direct Current Stimulation. Daily sessions with a total of 10 days intervention. Each intervention will take place with a 2mA intensity during 20 minutes. The current will be delivered by "Chattanooga Iontophoresis Dual Channel Delivery Device", that stands for a 2-channels tDCS device in which previous dosage can be set as default to maintain frequently used treatment parameters. Main features include (a) Beeping alerts if electrode fault for open current or high impedance, low battery, treatment completion or power left on; (b)automatic 30 second current ramp up and down during power on/off keeps patient comfortable; (c) Current can be set in 0.1 mA increments between 0.5 mA and 4 mA.

Timeline

Start date
2012-08-01
Primary completion
2013-08-01
Completion
2014-08-01
First posted
2012-06-20
Last updated
2013-12-16

Locations

1 site across 1 country: Brazil

Source: ClinicalTrials.gov record NCT01623726. Inclusion in this directory is not an endorsement.