Trials / Completed
CompletedNCT01614158
Assessment of Visual Field-related Endpoints in Patients With Non-arteritic Ischemic Optic Neuropathy
Pilot SINN; Assessment of Visual Field (vf)-Related Endpoints in Patients With Non-arteritic Ischemic Optic Neuropathy (N-AION)
- Status
- Completed
- Phase
- —
- Study type
- Observational
- Enrollment
- 16 (actual)
- Sponsor
- University Hospital Tuebingen · Academic / Other
- Sex
- All
- Age
- 18 Years – 80 Years
- Healthy volunteers
- Not accepted
Summary
This present research project intends to collect five quantitative test series: * perimetric examination using static stimuli, assessing the entire (80 degree) visual field with a fast thresholding algorithm (GATE) \[Schiefer 2008\] to know the extent/ magnitude of the visual field defect and its variability within the cohort and over time * D-BCVA, using FrACT \[Bach 2007\] and EDTRS chart \[Ferris 1982\] * RAPD (using swinging flashlight test). * IOP (using applanation tonometer) * RNFT and RNFV using Spectralis OCT (star scan, ring scan 2,8 mm, and volume scan) Optic disk morphology will be documented by fundus photography. This assessment of the above-mentioned data is needed in order to allow for estimation of the spontaneous course / fluctuation of the (quantified) functional and morphometric parameters of the N-AION patients during the follow-up period. This is essential for the estimation of the sample size of the subsequently intended SINN study, that is intended to compare different therapeutic strategies in N-AION patients.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | perimetry | perimetric examination using static stimuli, assessing the entire (80 degree) visual field with a fast thresholding algorithm (GATE) \[Schiefer 2008\] to know the extent/ magnitude of the visual field defect and its variability within the cohort and over time |
| OTHER | D-BCVA | D-BCVA using EDTRS chart |
| OTHER | RAPD | RAPD using swinging flashlight test |
| DEVICE | IOP | IOP using applanation tonometer |
| DEVICE | Spectralis OCT | RNFT and RNFV using Spectralis OCT (star scan, ring scan 2,8 mm and volume scan) |
| OTHER | Fundus photography | Optic disk morphology will be documented by fundus photography |
Timeline
- Start date
- 2009-04-01
- Primary completion
- 2011-02-01
- Completion
- 2011-02-01
- First posted
- 2012-06-07
- Last updated
- 2014-05-28
Locations
1 site across 1 country: Germany
Source: ClinicalTrials.gov record NCT01614158. Inclusion in this directory is not an endorsement.